Shrink Tank VC999 85.47i
Page 12/34
Art. no. 512.320
2009-11-17
4. Technical Data
Electrical Connection Values (Fig.1, Pos. 1)
Equipment as in EN 60204-1
230 V / 3 / 50 Hz
0.5 kW
10 AT
20.5 kW
60 AT
30.5 kW
100 AT
400 V / 3 / 50 Hz
0.5 kW
6 AT
20.5 kW
40 AT
30.5 kW
60 AT
208 V / 3 / 60 Hz
0.5 kW
10 AT
20.5 kW
60 AT
30.5 kW
100 AT
220 V / 3 / 60 Hz
0.5 kW
10 AT
20.5 kW
60 AT
30.5 kW
100 AT
380 V / 3 / 60 Hz
0.5 kW
6 AT
20.5 kW
40 AT
30.5 kW
60 AT
440 V / 3 / 60 Hz
0.5 kW
6 AT
20.5 kW
40 AT
30.5 kW
60 AT
575 V / 3 / 60 Hz
0.5 kW
6 AT
20.5 kW
40 AT
30.5 kW
40 AT
The connection values for your machine can be found on
the type label (19) on the left hand side of the machine.
Electrical connection can be made from above or below
(see section 8.1).
Output
Up to a max of 8 cycles / min.
Product Area
900 x 460 x 250 mm max 50 kg
Water Connection
(Fig. 1, Pos. 2)
R½“
Tank holds about 210 litres
Steam Connection
(Fig. 1, Pos. 3)
R½“ 6 - 8 bar
Steam needed to bring water from
20° to 90°C:
30 kg
Connection for Compressed Air
(Fig. 1, Pos. 4)
For compressed air hose ID 9 mm
6 - 8 bar
Uses 17 NL compressed air per cycle at 6 bar
Steam Exhaust
(Fig. 1, Pos. 5)
For steam exhaust pipe, outside diameter 160 mm.
Steam exhaust can be regulated manually
Water Discharge
(Fig. 1, Pos. 6)
Threaded joint R1¼“
Water Overflow
(Fig. 1, Pos. 7)
Threaded joint R1“
Weight
Weight (without accessories) 400 kg approx.
Standard Equipment
Electrical or steam heating
Cannot be operated with no water in tank
Steam exhaust (regulated by water temperature)
Automatic temperature control
Automatic level control of water
Automatic fault indication
Fully automatic microprocessor-controlled operating
cycle (automatic and continuous working)
Adjustable immersion time
Programmable water heating (timer)
Operator guidance by LCD display with option to change
language
Additional Equipment
In - and outlet rollers
Intake - and discharge conveyor
Outlet extension roller 500 mm
Outlet extension roller 900 mm
Noise Level when Operating
according to in DIN 45635
Preparation / Work place
70 dB(A)
Summary of Contents for 85.47i D
Page 4: ......
Page 21: ...Shrink Tank VC999 85 47i 2009 11 17 Art no 512 320 Page 21 34 Flow chart for program Level...
Page 23: ...Shrink Tank VC999 85 47i 2009 11 17 Art no 512 320 Page 23 34 Decalcifying program...
Page 24: ...Shrink Tank VC999 85 47i Page 24 34 Art no 512 320 2009 11 17 Flow chart ABC level...
Page 32: ...Shrink Tank VC999 85 47i Page 32 34 Art no 512 320 2009 11 17 16 Pneumatics diagram...
Page 33: ...Shrink Tank VC999 85 47i 2009 11 17 Art no 512 320 Page 33 34 17 Circuit diagrams...
Page 34: ...Shrink Tank VC999 85 47i Page 34 34 Art no 512 320 2009 11 17...