Installation, Operating & Maintenance Instructions
Series 615 DN 40 (I.D. 1.5”), RS485
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
289111EB
2013-02-05
77/96
Description
Required tool
Rep
la
c
e
o
-ri
n
g
s
a
t
p
la
te
14. Push in the o-ring equally around the plate
into o-ring groove
15. Plate with equal mounted o-ring
As
s
e
m
b
le
a
n
d
a
d
ju
s
t
p
la
te
16. Place the plate on the shaft in the valve
body
As
s
e
m
b
le
a
n
d
a
d
ju
s
t
p
la
te
17. Tighten plate screws to block.
18. Loosen the plate screws a quarter turn
counter clockwise.
Fact:
Plate is now movable on shaft and ready
to sliding into valve seat. Proceed with step
19.
Allen Wrench
3mm
19. Connect electrical POWER connection at
valve
Attention!
Valve does synchronize automatically
and moves the plate into sit of valve
body (close position).
20. Disconnect electrical POWER connection
Attention!
Keep fingers out of the valve
opening during plate movement!