3.11.3.2 Required information for support (in case of unsuccessful tuning procedure):
Go to „Tools / Create Diagnostic File‟ in „Control View‟ resp. „Control Performance Analyzer‟ and save file
Pressure / flow / gas conditions to be controlled
Chamber volume
Pumping speed (l/s) and pump type (e.g. turbo pump)
System description
Problem description
Send diagnostic file with and all required information to
3.12 RS485 interface
3.12.1 Settings
The factory default setting of the RS485 interface is shown in the table below. It might be changed to fit the application by
using the Control View software, the Control Performance Analyzer software or the Service Box 2.
Baud rate
Data bits
Stop bits
Parity
9600
7
1
none
Address
Duplex
Digital input OPEN
Digital input CLOSE
10
half duplex
not inverted
not inverted
3.12.2 Schematics
This interface allows for remote operation by means of a command set based on the RS485 protocol.
In addition there are 2 digital inputs and 2 digital outputs. Digital inputs may be operated either by switches or by voltage
sources.