8303
Varec, Inc.
75
Dynamic Parameters
Function
Level
IEEE Floating point value representing the tank level. The data is
returned in the format specified during the configuration of the gauge.
GaugeStatus
Integer value indicating status of the gauge (Integer Register 6). Values
are:
0x0001: Bad Level
0x0002: Bad Temp
0x0004: Bad EE
0x0008: Bad EE Checksum
0x0010: Bad RAM
0x0020: Bad EEPROM
0x0040: Local Modifications
0x0080: No Calculation
0x0100: CFG Error
0x0200: Calc Error
0x0400: Bad CPU Board
0x0800: Bad Comm Board
0x1000: Low Encoder Battery
Rate
Level Rate.
TankLevel
Tank Level.
Ullage
Measured Distance. Distance from radar to product.
Analog1 through Analog3
4 to 20 mA value %
Temp1 through Temp5
Floating point value representing the product temperature at various
levels. The data is returned in the format specified during the
configuration of the gauge. Temp1-Temp16 can be converted from
Metric to English (or vice-versa) by setting the TempConvert parameter
of the appropriate MSCAN or RKSCN point.
TempFilter
Temp in Liquid parameter. Bits 0 – 13 indicate if Temp sensors 1 – 14
are submerged in liquid. Bit 14 indicates a System Error. Bit 15 indicates
a Temp calibration error.
0x0001: Temp 1 is in Liquid
0x0002: Temp 2 is in Liquid
0x0004: Temp 3 is in Liquid
0x0008: Temp 4 is in Liquid
0x0010: Temp 5 is in Liquid
0x0020: Temp 6 is in Liquid
0x0040: Temp 7 is in Liquid
0x0080: Temp 8 is in Liquid
0x0100: Temp 9 is in Liquid
0x0200: Temp 10 is in Liquid
0x0400: Temp 11 is in Liquid
0x0800: Temp 12 is in Liquid
0x1000: Temp 13 is in Liquid
0x2000: Temp 14 is in Liquid
0x4000: System Error
0x8000: Temp Calibration error
Summary of Contents for 8300 series
Page 2: ......
Page 6: ...Tank Gate Interface iv Installation and Operations Manual ...
Page 14: ...Overview Tank Gate Interface 4 Installation and Operations Manual ...
Page 50: ...Software Description Tank Gate Interface 40 Installation and Operations Manual ...
Page 52: ...Dual RS 485 MODBUS Software Blocks Tank Gate Interface 42 Installation and Operations Manual ...
Page 56: ...Tank Gate Interface 46 Installation and Operations Manual ...
Page 68: ...Tank Gate Interface 58 Installation and Operations Manual ...
Page 100: ...Tank Gate Interface 90 Installation and Operations Manual ...
Page 112: ...Tank Gate Interface 102 Installation and Operations Manual ...
Page 115: ...8303 Installation Varec Inc 105 s Figure 7 2 Tank Gate Interface Dimensions 197 204 125 ...
Page 148: ...Appendix Order Codes Tank Gate Interface 138 Installation and Operations Manual ...
Page 149: ......