Blower Housing
1. Remove 4 fasteners (
A
, Figure 49) to release wire guard
(
B
) from coupling nuts.
49
2. Remove 3 fasteners with flat washers (
C
) to release
debris screen (
D
) and triangular spacer (
E
) from rotating
studs.
3. Remove 4 coupling nuts (
F
, Figure 50) from cylinder
posts.
50
4. Remove blower housing (
G
) from engine and set aside.
Voltage Regulator
Your engine may be equipped with either a 20 amp or a 20/50
amp voltage regulator. The 20/50amp voltage regulator has a
capacitor mounted to a bracket atop the regulator.
1. Disconnect the voltage regulator to stator connector. If
equipped with a 20 amp regulator, see (
A
, Figure 51). if
equipped with a 20/50 amp regulator, see (
A
, Figure 52).
51
2. Remove the starter motor positive terminal nut and then
remove the voltage regulator wire from the terminal.
20 amp voltage regulator, see (
B
, Figure 51). The
20/50 amp voltage regulator has an additional wire, the
capacitor wire, that connects to the starter motor positive
terminal, see (
B
3. Remove the 2 voltage regulator mounting fasteners (
C
,
58
Summary of Contents for BIG BLOCK M540000
Page 46: ...Special Tools Image Chart 30 47...
Page 74: ...84 75...
Page 75: ...85 76 vanguardpower com...
Page 81: ...94 82 vanguardpower com...
Page 111: ...Vanguard Model 540000 145 112 vanguardpower com...
Page 113: ...Vanguard Model 610000 146 114 vanguardpower com...
Page 136: ...176 137...