6. Connect the ignition switch start wire (
B
, Figure 205) to
the starter motor terminal.
205
7. Install the voltage regulator wire onto the starter motor
positive terminal (
A
). Start by hand the terminal nut.
Tighten to
45 lb-in
(5 Nm).
Voltage Regulator
Your engine may be equipped with either a 20 amp or a 20/50
amp voltage regulator. The 20/50amp voltage regulator has a
capacitor mounted to a bracket atop the regulator.
1. Install the regulator into the engine block. Align the
regulator mounting holes with the threaded holes in the
engine block.
2. Start by hand the 2 mounting fasteners (
C
, Figure 206).
Tighten to
90 lb-in
(10.2 Nm).
206
3. Connect the stator wire harness connector to the voltage
regulator connector (
A
).
NOTE:
The 20 amp alternator has a single 2-wire connector.
The 20/50 amp alternator has double 2-wire connectors.
4. Connect the RED voltage regulator wire with ring
terminal connector to the positive starter motor terminal
(
B
).
NOTE:
On 20/50 amp alternator equipped engines, an
additional wire, from the capacitor, needs to be installed
on the starter motor positive terminal. See Figure 207 as a
reference.
207
5. Start by hand the starter motor positive terminal nut.
Tighten to
45 lb-in
(5 Nm).
151
Summary of Contents for BIG BLOCK M540000
Page 46: ...Special Tools Image Chart 30 47...
Page 74: ...84 75...
Page 75: ...85 76 vanguardpower com...
Page 81: ...94 82 vanguardpower com...
Page 111: ...Vanguard Model 540000 145 112 vanguardpower com...
Page 113: ...Vanguard Model 610000 146 114 vanguardpower com...