3.15 Monitoring values
Monitor value, I/O
Value
ID
V2.4.1
Slot A DIN 1,2,3
15
V2.4.2
Slot A DIN 4,5,6
16
V2.4.3
Slot B RO 1,2,3
17
V2.4.4
Analogue input 1
%
59
V2.4.5
Analogue input 2
%
60
V2.4.6
Analogue input 3
%
61
V2.4.7
Analogue input 4
%
62
V2.4.8
Analogue input 5
%
75
V2.4.9
Analogue input 6
%
76
V2.4.10 Slot A AO1
%
81
Monitor value, Temperature inputs
Value
ID
V2.5.1
Temperature input 1
° C/F
50
V2.5.2
Temperature input 1
° C/F
51
V2.5.3
Temperature input 1
° C/F
52
V2.5.4
Temperature input 1
° C/F
69
V2.5.5
Temperature input 1
° C/F
70
V2.5.6
Temperature input 1
° C/F
71
Monitor value, Timer functions
Value
ID
V2.7.1
TC 1, TC 2, TC 3
1441
V2.7.2
Interval 1
1442
V2.7.3
Interval 2
1443
V2.7.4
Interval 3
1444
V2.7.5
Interval 4
1445
V2.7.6
Interval 5
1446
V2.7.7
Timer 1
1447
V2.7.8
Timer 2
1448
V2.7.9
Timer 3
1449
V2.7.10 Real-time clock
1450
Monitor value PID regulator
Value
ID
V2.8.1
PID1 reference value
var.
20
V2.8.2
PID1 feedback
var.
21
V2.8.3
PID1 feedback (1)
var
15541
V2.8.4
PID1 feedback (2)
var
15542
V2.8.5
PID1 error value (difference)
var.
22
V2.8.6
PID1 output value
%
23
V2.8.7
PID1 status
24
Monitor value, External PID regulator
Value
ID
V2.9.1
External PID reference value
var.
83
V2.9.2
External PID actual value
var.
84
V2.9.3
External PID error value
(difference)
var.
85
V2.9.4
External PID output value
%
86
V2.9.5
External PID status
87
Multi-pump monitor
Value
ID
V2.10.1
No. of motors in operation (active)
30
V2.10.2
Autochange
1113
V2.10.3
Next autochange
1503
V2.10.4. Operating mode
1505
V2.10.5
Multi-pump, status
15507
V2.10.6
Communication status
15506
V2.10.7
Pump (1) running time
h
15510
V2.10.8
Pump (2) running time
h
15511
V2.10.9
Pump (3) running time
h
15512
V2.10.10 Pump (4) running time
h
15513
V2.10.11 Pump (5) running time
h
15514
V2.10.12 Pump (6) running time
h
15515
V2.10.13 Pump (7) running time
h
15516
V2.10.14 Pump (8) running time
h
15517
Monitor value, Maintenance counters
Value
ID
V2.11.1 Maintenance counter 1
h/kRev 1101
Monitor value, Fieldbus
Value
ID
V2.12.1
to
V2.12.20
Various Fieldbus values
864
to
883
Monitor Drive Customizer
Value
ID
V2.13.1
to
V2.13.11
Various Drive Customizer values
15020
to
15200
Monitor value, Base
Value
ID
V2.3.1
Output frequency
Hz
1
V2.3.2
Reference frequency
Hz
25
V2.3.3
Motor speed
RPM
2
V2.3.4
Motor current
A
3
V2.3.5
Motor torque
%
4
V2.3.7
Motor shaft power
%
5
V2.3.8
Motor shaft power
kW/hp
73
V2.3.9
Motor voltage
V
6
V2.3.10 DC link voltage
V
7
V2.3.11 Unit temperature
o
C
8
V2.3.12 Motor temperature (calculated)
%
9
V2.3.13 Motor preheater
1228
V2.3.15 kWh trip counter low
kWh
1054
V2.3.16 kWh trip meter high
kWh
1067
Monitor value, Extras & Advanced
Value
ID
V2.6.1
Frequency convertor status word
43
V2.6.2
Ready
78
V2.6.3
Application status word 1
89
V2.6.4
Application status word 2
90
V2.6.5
DIN status word 1
56
V2.6.6
DIN status word 2
57
V2.6.7
Motor current 1 decimal
45
V2.6.8
Frequency reference source
1495
V2.6.9
Last active error code
37
V2.6.10 Last active error ID
95
V2.6.11 Last active alarm code
74
V2.6.12 Last active alarm ID
94
V2.6.13 Status motor regulator
77
V2.6.14 Motor shaft power 1 decimal
kW
98