Electrical wiring
through the left
hand side of the
appliance case
Install Electrical Wiring
(if needed)
This section provides information to install the electric
pre-wiring required for use with the 1195CFK Circulating
Fan Kit or GV60WIFI WiFi module.
All wiring must be done by a quali
fi
ed electrician in
accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA
70 or the Canadian Electrical Code, CSA C22.1.
Electrical Requirements
1195CFK—120 V, 60 Hz, less than 1 amp
GV60WIFI—6 VDC (from receiver), less than 1 amp
General Requirements
Both optional 1195CFK and GV60WIFI kits require a
GV60VM power supply (V-module), which includes a
three-prong grounded plug to plug into a grounded
receptacle, to be installed within the
fi
replace enclosure
by a quali
fi
ed electrician.
Notes
• We recommend connecting the electrical box even if
the optional accessories have not been purchased. It
is much easier to wire before wall
fi
nish is applied.
• Wiring within the receptacle enclosure must have a
minimum 90°C temperature range.
• Wire nuts not included.
• The 1195CFK kit includes a junction box and recep-
tacle as well as a V-module. See instructions package
with the kit.
• The GV60WIFI kit includes a WiFi module only.
It requires H5/6-WPK—WiFi Power Kit J-box and
GV60VM—V-module (all sold separately) if the fan kit
is not installed. See instructions packaged with the kit.
Installation
WARNING
Optional electrical accessories ARE NOT
ALLOWED when adapting appliance for
outdoor use.
Electrical Wiring
Installation
Thread the power supply cable through the cable clamp
(not provided) and through the hole in the lower left
hand side of the
fi
replace casing. Do not tighten the
clamp yet.
If simply roughing in power at this point, ensure
wiring is not live or terminate at this location in a
temporary metal junction box using wire nuts to
cap wires.
1-1/4”
[32 mm]
5-1/2”
[140 mm]
Electrical
access hole
7/8” [22 mm]
diam.
Electrical access—left side view