18
Planning
Framing
Min 1”
[26 mm]
required
clearance
to vertical
SLSHDHFWV
cavity depth
Approx. 39-1/4” [997 mm]
6WDQGR
Fireplace -
Left Side View
*Approx. 49-3/4” [ 1266 mm] with 12” vent pipe
ȋ>PP@WRXQGHUVLGHRIFRPEXVWLEOHFDYLW\
ȋSLSHVHFWLRQ
1/2”
[13 mm]
beyond
VWDQGR
Approx. 31” [787 mm]
*Approx. 42-1/4” [ 1073 mm]
Fireplace -
Left Side View
12” pipe section
*Approx. 52-3/4” [ 1340 mm] with 12” vent pipe
40” [ 1016 mm] to underside of combustible cavity
Vertical Takeo
ff
Horizontal Takeo
ff
Venting Considerations
*Notes—ALL venting considerations
• Dimensions of venting are based on
using Dura-Vent elbows. Elbow curve
radius dimensions will vary when using
other brands. In general, other brands
have slightly bigger radius.
• 3 inches clearance to combustibles
required above horizontal pipe. Slope
horizontal pipe upwards 1/4 inch per
foot. 1 inch clearance required around
sides and bottom of horizontal pipe and
around vertical pipe.
• When calculating e
ff
ective pipe lengths
subtract approximately 1-1/2 inch for
pipe joint - for example, a 12 inches pipe
section will add approximately 10-1/2
inches overall.