Venting
Co-linear Conversion
Co-linear adapter
46DVA-34CLAA or
46DVA-GCL34
Min. 12”
vertical
rise
Flashing
1x 3” air inlet
liner and
1x 4” exhaust
liner
Fireplace
Approved 3 x 4
co-linear termination
Listed clearances
to combustibles
stated in this
manual apply
Framed
wall
3” min. bend radius
for air inlet liner
4” min. bend radius
for exhaust liner
Co-linear
adapter
3” air
inlet
liner
4” exhaust
liner
Co-linear installation into adjacent existing chimney
Installation Into an Adjacent Chimney
Required accessories:
• Co-axial to co-linear adapter at appliance 46DVA-
34CLAA, 46DVA-GCL34 or equivalent;
• 2 lengths of 2-ply,
fl
exible chimney liner approved for
venting gas appliances:
• 1 x 3-inch diameter for air inlet and
• 1 x 4-inch diameter for exhaust;
• Co-linear termination kit 3 x 4 and
fl
ashing or co-linear
to co-axial adapter and either high wind vertical vent
terminal cap or a low pro
fi
le vertical termination.
Note:
A 3” diameter exhaust liner may be used if
conditions will not allow for the 4” exhaust liner.
Cold start-up problems may be experienced however
when using a 3” exhaust liner.
This appliance must be completely framed and
maintain clearances to combustibles as shown
in this manual.