100
Appendix D - HeatShift System
!
Ʉ
WARNING
DO NOT INSTALL 1270RBK Remote Blower
Kit to any of these 4 takeo
s.
Ʉ
WARNING
A l l F O U R ( 4 ) t a k e o f f s M U S T B E
C O N N E C T E D T O P L E N U M ( S ) .
Remove Convection Ba
ɞ
e
To be e
ective the HeatShift Kits require that a
convection ba
ɞ
e located above the
ȴ
rebox inside the
appliance case be removed to allow the hot air
ȵ
ow to
convect upwards into ducts installed on the
ȴ
replace.
Remove the convection ba
ɞ
e from the
appliance. It is held in place by screws located
right behind the upper edge of the
ȴ
replace
opening (3 screws/ba
ɞ
e for 1100’s, 4 for 1400’s
ba
ȵ
e). Recycle this panel as it is no longer
needed.
Convection
ba
ɞ
e to be
removed
Convective
airflow with
baffle
removed
Take-off
collar
Firebox
Re-direction of convected air after removing ba
ɞ
e
Convective
air
ȵ
ow with
ba
ɞ
e in place
Appliance top panel—shown transparent
for clarity
Remove convection ba
ɞ
e—
1100J & M, 1150J, 1400J, K & M
Conve
ction b
a
ɞ
e
Install HeatShift collars
1. Remove the four cover plates on top of the appli-
ance case (6 screws each).
2. Install the collars on the holes on top of the appli-
ance’s case (6 screws each).
1100J & M, 1150J, 1400J, K & M
1100J & M, 1150J, 1400J, K & M
Appliance top shown transparent for clarity
Remove convection ba
ffl
e—1100M
Conve
ction B
a
ffl
e