background image

60

 Spare Parts

Code

Description

Part 

Number

1

Heat shield

4003049

2

45 degrees 

fl

 anged elbow

0945M

3

Elbow gasket

4002999

4

Top stand-offs (2)

4005408

5

Restrictor plate

4003017

6

Take-off cover (2)

4003046

7

Liner panels anchors (2)

4001283

8

LH Window latch assembly

4002770

9

RH Window latch assembly

4002766

10

Top panel support

4002963

11

Cable hole cover

4003038

12a

Air de

fl

 ector LH

4003308

12b

Air de

fl

 ector RH

4003492

13

Window assembly

4003567

14

Black metal platform

4004138AH

15a

Burner module assembly NG

4003747

15b

Burner module assembly LPG

4003748

16

Burner

4003589

18

Platform supports (2)

4002908

19

Pilot shield

4003018AH

20a

Pilot assembly NG

4000727

20b

Pilot assembly LPG

4000728

21

Thermocouple

4000061

22a

Pilot injector NG #51

4000735

22b

Pilot injector LPG #30

4000736

23

Pilot tube

4000732

24

Pilot hood 2-

fl

 ame

4000730

25

Extended nut

4001855

26

Electrode

4001856

27a

Burner location bracket

4002902

27b

Burner end location bracket

4002903

28a

Injector elbow NG 82-1000

4003985

28b

Injector elbow LPG 92-380

4004145

29

Air shutter

4002907

30

Burner gasket (air shutter)

4002906

31

Gasket silicone

620C016

32

Burner module plate

4002775

33

Gaskets module plate, long (2)

3000400

34

Gaskets module plate, short (2)

3000399

35

Pilot sealing plate

4002910

36

Valve to elbow pipe assembly

4003749

37a

GV60 valve assembly NG

4003986

Code

Description

Part 

Number

37b

GV60 valve assembly LPG

4003987

38

Thermocouple interrupter

4001037

39

Pipe s/s 

fl

 ex

4000345

40

Handset wall holder

9000008

41

Handset G6R H3T5-ZV (BJ)

4001910

42

Receiver G6R-R3AM-ZV (CP)

4001911

43

Wire harness GV60

4001187

44

Cable interrupter 500 mm

4002096

45

Ignition cable sleeve 530 mm

4002244

46

Ignition cable 500 mm

4001039

47

Remote battery & Wall switch kit

RBWSK

47a

Junction box

4005527

47b

Cover plate & 4 screws

4005526

47c

Battery holder

4005525

47d

Cable tie

4005524

47e

Harness assembly

4005523

47f

Plate with magnets

4005391

47g

Long screws (2)

4001444

47h

Wall switch with 2 screws

4005522

47i

Battery cover assembly

4005390

49

Liner panels - complete set

Fluted Black Liners

1715FBL

Re

fl

 ective Glass Liners

1725RGL

50

Rear panel

Fluted Black - centre panel only

4003955

Glass (3)

4004275

50a

Rear panel

Fluted Black - sides (2)

4003727

Glass

-

51

LH side panel

Black

4003071

Glass

4004273

52

RH side panel

Black

4003072

Glass

4004274

53

Top panel

Black (2)

4003728

Black (2)

4003728

54

Murano Glass Fire

1700DGM

55a

Glass panel 401 x 66 mm

4003746A

55b

Glass panel 401 x 82 mm

4003746B

55c

Glass panel 119.5 x 46 mm

4003746C

OWNER’S 
INFORMATION

Summary of Contents for 1700JN

Page 1: ...ble en fran ais sur demande This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used...

Page 2: ...arbon Monoxide Detector requirements on page 18 Designed and Manufactured by for Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC CANADA V7H 3B1 Tel 604 984 3496 Fax 604 984 0246 www...

Page 3: ...BE PLACED on or near the appliance This unit MUST be used with a vent system as described in this installation manual NO OTHER vent system or components MAY BE USED This gas fireplace and vent assemb...

Page 4: ...ysical barrier is strongly recommended if there are young children or at risk individuals in the house Install an approved after market safety gate to keep toddlers young children and other at risk in...

Page 5: ...cularly the GLASS window DO NOT LET CHILDREN touch the glass or any parts of your fireplace even after it is turned off as it is still hot USE THE BARRIER SCREEN provided with the trim or a GATE to re...

Page 6: ...ducts with varying results The following are recommendations only and are not meant to guarantee results NOTE This is a problem beyond Miles Industries control and is not covered under warranty Clean...

Page 7: ...When cleaning make sure that no par ticles are brushed into the slots of the burner To refit the window 1 Place the window in its bottom railing Ensure to remove any vermiculite glass or shale particl...

Page 8: ...periodic check of the pilot and burner flames should be made Check after the fire has been on for at least 30 minutes The pilot flame must cover the tip of the thermocouple probe The main burner flame...

Page 9: ...ription when requesting spare parts To replace the batteries The battery compartment is located next to the wall switch in the vicinity of the fireplace Its front plate is attached with magnets to the...

Page 10: ...s is off when the handle is perpendicular with the pipe How to Ensure Your Fireplace Cannot Be Turned ON Inadvertently You can use one of the two following methods to ensure that your fireplace will n...

Page 11: ...confirm the ignition is in process Once pilot ignition is confirmed there is main gas flow After main burner ignition the handset will automatically go into manual MAN control mode Press OFF button Wh...

Page 12: ...he hour Press small flame button to set the minute Press OFF or simply wait to return to MAN mode Double click large flame button Flame automatically goes to high fire HI will be displayed Manual Mode...

Page 13: ...programming SETTING THE DAYTIME TEMPERATURE SETTING THE NIGHTTIME SETBACK TEMPERATURE Default Settings sun 23 C 74 F Default Settings moon OFF Press large flame button to increase Nighttime Setback Te...

Page 14: ...TIMER moon while the time flashes Press large flame button to set the hour Press large flame button to set the hour Press small flame button to set the minutes Press small flame button to set the minu...

Page 15: ...ge in flame height for a period of 6 hours the appliance goes into pilot mode NOTE In TEMP or TIMER modes the flame height will vary according to room temperature The appli ance will continue to work...

Page 16: ...Shale Set Liners choose one 1715FBL Linear Fluted Black Liner Set 1725RGL Linear Reflective Glass Liner Set Add 1725RGL 3 Glass Retainer Kit Trims choose one Barrier Screen 1750 Linear 5 1 4 Surround...

Page 17: ...oor If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 3 AUTOMATIC IGNITION MAN knob 2 in ON position Ensure Flame Adjustment knob...

Page 18: ...d a battery operated carbon monoxide detector with an alarm shall be installed 2 APPROVED CARBON MONOXIDE DETECTORS Each carbon monoxide detector as required in accordance with the above provisions sh...

Page 19: ...ded with the appliance or equipment installation instructions and 2 The special venting systems shall be Product Approved by the Board and the instructions for that system shall include a parts list a...

Page 20: ...Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 For installations at elevations above 4 500 feet 1 370 m in Canada please consult provincial and or local authorities having jur...

Page 21: ...ag ge 23 WARNING Some materials or items although safe may discolor shrink warp crack peel and so on because of the heat produced by the fireplace Avoid placing candles paintings photos and other item...

Page 22: ...3 mm 386 18 5 8 473 mm 3 3 4 95 mm 4 102 mm 20 508 mm 32 3 8 822 mm 33 1 8 841 mm 14 1 2 2 369 m mm 9 3 8 238 m mm 52 1321 mm 49 11 16 1262 mm 1270RBK Remote Blower Kit outlet remove plate LDK Duct Ki...

Page 23: ...Face of Cement Board Mantel Height from Bottom of Unit Fireplace Opening Ceiling 24 Min to Ceiling 44 42 40 38 23 7 8 9 3 8 4 minimum to combustible or non combustible hearth Note Use of the optional...

Page 24: ...24 49 11 16 Fireplace Opening Wall Min 4 to wall or combustible mantel leg Face of Finished Wall FIREPLACE Combustible Sidewall Mantel Leg Top View Mantel Hearth Clearances QUALIFIED INSTALLER...

Page 25: ...GUIDE D INSTALLATION NON COMBUSTIBLE MATERIALS ONLY READ INSTRUCTIONS MAT RIAUX INCOMBUSTIBLES SEULEMENT CONSULTEZ LE GUIDE D INSTALLATION Min 60 1524 mm 50 1270 mm Min 44 1 2 1130 mm Min 20 1 2 521 m...

Page 26: ...ox 10 3 4 274 mm from back surface of wall finish to front surface of appliance case w no vent offset 15 3 16 386 mm 14 1 2 369 mm 9 3 8 238 mm 19 1 4 489 mm Fireplace Opening PARTIAL SHELF top outlet...

Page 27: ...Dimensions of venting are based on using Dura Vent elbows Elbow curve radius dimensions will vary when using other brands In general other brands have slightly bigger radius Minimum 12 inches vertica...

Page 28: ...sembly up to 8 inches in thickness A non combustible wall can be of any thickness up to the maximum horizontal run of vent pipe allowed for the particular installation Framing Vent in Combustible Wall...

Page 29: ...MBLE PIPE LENGTH PIPE LENGTH PIPE LENGTH PIPE LENGTH 90 ELBOW CEILING FIRESTOP ATTIC FIRESTOP ATTIC INSULATION SHIELD FLASHING STORM COLLAR VERTICAL TERMINATION PIPE LENGTH 90 ELBOW 90 ELBOW Co axial...

Page 30: ...e and run can be used as long as they are within the allowable limits shown on the chart below 5 A maximum of 4 x 90 degrees elbows or equivalent 2 x 45 degrees 90 degrees can be used Excludes the 45...

Page 31: ...of restriction required depends on the vertical rise in the venting system and to a lesser degree the horizontal run and number of elbows The amount of restriction is based on laboratory tests The ide...

Page 32: ...bly located within 15 feet 4 6 m below the terminal 36 90 I Clearance to service regulator vent outlet 36 90 J Clearance to non mechanical air supply inlet to the building or the combustion air inlet...

Page 33: ...two lengths of 2 ply flexible chimney liner one 3 diameter liner for intake and one 4 diameter liner for exhaust both approved for venting gas appliances a 3 x 4 co linear termination kit and flashing...

Page 34: ...on For installation of the adapter to the appliance see the instructions supplied with the 1156CLA Co linear Venting Example of co linear terminal configurations 9 3 8 11 11 16 3 exhaust collar 1 1 2...

Page 35: ...sories trim decorative lighting etc will be installed with this fireplace The venting configuration 2 Unpack the appliance removing all items packed inside and around the appliance 3 Check that you ha...

Page 36: ...nal LDK Duct Kit s take off collars to appliance if used See installation instructions packed with the LDK kits for details Fit the Appliance into Framing 1 Remove the 4 screws retaining the engine to...

Page 37: ...terials Pre drill cement board with oversized holes and do not over tighten screws to avoid cracking due to heat expansion Standard gypsum wall board may be used beyond the perimeter of the cement boa...

Page 38: ...appliance can exceed 250 F Below are some tips on how to best avoid any cracking Allow materials to dry thoroughly before finishing the wall Cement board has the ability to absorb up to 30 percent of...

Page 39: ...red and the duplex receptacle will need to be split to ensure separate control of fan and lighting The duplex receptacle and box must be located as per these instructions Wiring within this box must h...

Page 40: ...ion against sulfur compounds Unions in gas lines should be of ground joint type The gas supply line must be sized and installed to provide a supply of gas sufficient to meet the maximum demand of the...

Page 41: ...the warranty Consult your dealer in case of damages Pressure Test Points The minimum supply pressure is given in the section Specifications of this manual page 20 All piping and connections must be te...

Page 42: ...wards the middle to fit into the middle section Place the panel s right section on the ledge above the ports of the rear of the firebox The section sits on the ledge behind the tabs with its plain edg...

Page 43: ...the side panel anchors on each side of the firebox 9 Place the remaining rear panel s section behind the left side panel and fit its stepped edge to the stepped edge of the rear panel s center section...

Page 44: ...possible to maximize the air gap behind the burner 2 Fill a small container with the equivalent of approximately 3 cups 750 ml of vermiculite from the bag supplied 3 Carefully spread the vermiculite...

Page 45: ...the log s left peg in the front hole for natural gas NG fire LPG fire Place the log s left peg in the rear hole for propane gas LPG fires 2 Place the rear left log as indicated 3 Place the front left...

Page 46: ...6 Place centre cross log to rear log as indicated Pivot tail end so tip is just inside fireplace window line 7 Some vermiculite may be added outside the burner on the platform if desired 8 Place the r...

Page 47: ...t supplied Murano Glass Fire Kit which contains 1 bag of clear fireglass 8 pieces glass panels Installation Carefully unpack the kit 1 Install the steel platform around the burner as indicated The ope...

Page 48: ...n the burner one at each end and one in the middle as indicated The rocks should not sit on top of the burner ports but can overhang slightly Note Although these rocks can be installed after the shale...

Page 49: ...ree rocks Do not overfill 3 Install some of the rocks around the shale bed according to the image shown below Note Some of the rocks may overhang slightly over the burner edge 4 Add the twigs to the r...

Page 50: ...ut any rock on the pilot shield Do not put more rocks on the shale The acceptable variations are only for rocks installed on the black platform outside of the shale bed or pilot shield Pilot shield Su...

Page 51: ...as indicated Hot Glass Warning Plate WARNING Failure to install the window correctly can leak carbon monoxide affect the performance of the fireplace damage components cause overheating resulting in...

Page 52: ...th Velcro bands 1 Pull out the receiver from its location to connect the battery holder and wall switch 2 Feed the white connector end of the harness assembly through side holes in fireplace liner bod...

Page 53: ...battery cover assembly 12 Position battery holder to rear face and secure together with cable tie note clearance is required for battery snap connection 13 Make the snap connection load 4 AA alkaline...

Page 54: ...flame up and down using the remote control to confirm that the full range of inputs is achieved see the remote control operation instructions on pages 11 15 Set Aeration if necessary Light the fire an...

Page 55: ...his holder is not required in all installations but is provided as an optional feature for those customers who wish to mount the remote handset to the wall To install the holder to the wall find a con...

Page 56: ...56 Wiring Diagram Wall Switch Kit GV60 Wiring Diagram Remote Battery Holder 4 AA Batteries 5 pin connector 9 Volt connector QUALIFIED INSTALLER...

Page 57: ...M CFAA3 95090390 Co linear Flex Connector 46DVA ADF Co axial to Co linear Adapter 46DVA GCL6 TM 4CAA6 4DCAB336 1156CLA5 6 9401064336 Co linear to Co axial Adapter 46DVA GK TM 4CTA 4DCAT33 Aluminum Fle...

Page 58: ...SK 949606001 Masonry Flashing TF 4MF New Siding Flashing 658NSFK Various Venting System Parts Wall Thimble 46DVA WT 4DT WT TM 4WT SV4RSM 4DWT 949064U Storm Collar 46DVA SC 4DT SC TM SC SV4AC 4DSC 9496...

Page 59: ...r damage to the unit due to i Improper installation operational or environmental conditions ii Inadequate ventilation in the area or competition for air from other household equipment or appliances ii...

Page 60: ...Gaskets module plate long 2 3000400 34 Gaskets module plate short 2 3000399 35 Pilot sealing plate 4002910 36 Valve to elbow pipe assembly 4003749 37a GV60 valve assembly NG 4003986 Code Description P...

Page 61: ...69 White beach pebble 2 4003084 70 Black beach pebble 2 4003085 71 Small beige beach pebbles 2 4003087 72 Grade 1A vermiculite bagged 4002940 73 Hot glass warning plate 4003093 74 Rocks Shale Set 171...

Page 62: ...1 2 3 89 89 4 4 5 6 11 12b 9 13 14 73 8 10 90 12a 53 51 50 52 49 50a 50a 53 15a 15b 16 18 19 20 26 27a 27b 28a 28b 29 30 31 32 33 34 35 37a 37b 36 39 38 47a 47b 47c 47d 47e 47f 47g 47h 47i 7 7 Spare...

Page 63: ...tion provided will be used for customer records only Online Warranty registration at www valorfireplaces com Cut out page fill information and mail to Miles Industries Ltd Fireplace Information Model...

Page 64: ...hut Thank you for choosing a Valor Product Postage needed Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty registration at www valorfireplace...

Reviews: