Appendix A - Parameters
MC083 - VCX Service Manual
190
DS-TCMx
Index
(Hex)
Sub-
Index
(Hex)
Name
Object
Type
Data
Type
Access
Type
Comment
Default
Min
Max
7
Consecutive Fault
Alarm - Mode
VAR
U16
RW
5 = Latched Output
6 = Latched Output,
Vmin dependent
7 = Momentary Output,
Vmin dep.
8 = Momentatry Output
7
5
8
8
Consecutive Fault
Alarm - Output 1
VAR
U16
RW
0 = No Output
1 = Relay 1
2 = Relay 2
3 = Buzzer
2
0
3
A
Number of
Consecutive Faults
VAR
U16
RW
5
1
100
B
Consecutive Fault
Alarm - Activation
Time
VAR
U16
RW
Only used in Mode 2, 7
and 8
20
0
255
11
Alarm Light - Mode
VAR
U16
RW
1 = Latched Output
(until next good)
2 = Latched Output,
Vmin dependent
3 = Momentary Output,
Vmin dep.
4 = Momentatry Output
1
1
4
13
Alarm 3 - Output 2
VAR
U16
RW
See Alarm Reference
for details
0
0
9
14
Alarm Light -
Maximum Time
VAR
U16
RW
Used in Mode 3+4 only
20
0
255
15
Alarm Light -
Minimum Time
VAR
U16
RW
Used in Mode 3+4 only
10
0
255
16
Alarm Buzzer -
Mode
VAR
U16
RW
1 = Latched Output
(until next good)
2 = Latched Output,
Vmin dependent
3 = Momentary Output,
Vmin dep.
4 = Momentatry Output
4
1
4
18
Alarm 4 - Output 2
VAR
U16
RW
See Alarm Reference
for details
0
0
9
19
Alarm Buzzer -
Maximum Time
VAR
U16
RW
Used in Mode 3+4 only
20
0
255
1A
Alarm Buzzer -
Minimum Time
VAR
U16
RW
Used in Mode 3+4 only
10
0
255
1C
Markingvalve - Ton
VAR
U16
RW
Valve -On-
Compensation Time
45
0
255
1D
Markingvalve - Toff
VAR
U16
RW
Valve -Off-
Compensation Time
45
0
255
1E
Markingvalve -
Tmin
VAR
U16
RW
Valve Minimum
Activation Time
15
0
255
1F
Markingvalve -
Type
VAR
U16
RW
See Valve Type
Reference for details
0
0
49
20
Markingvalve -
Vmin
VAR
U16
RW
Minimum Speed
0
0
3000
27
Markingvalve -
Delay
VAR
U16
RW
0
0
65535
29
Markingvalve -
Length
VAR
U16
RW
0
0
65535
50
Ejector (Top) - Ton
VAR
U16
RW
Upper Ejector Valve -
On- Compensation
Time
120
0
500
Summary of Contents for VCX
Page 1: ...VCX Service Manual For Internal Use Only Manual Number MC083 Revision Date 5 2022 ...
Page 4: ......
Page 10: ...Section 1 Introduction MC083 VCX Service Manual 10 ...
Page 18: ...Section 2 Safety and Use MC083 VCX Service Manual 18 ...
Page 31: ...MC083 VCX Service Manual Section 3 Basic Features 31 Inspection Control Module ICM ...
Page 37: ...MC083 VCX Service Manual Section 3 Basic Features 37 Tracking Control Module TCM Cube X49 ...
Page 50: ...Section 3 Basic Features MC083 VCX Service Manual 50 Tracking Control Module TCM MARS Ejector ...
Page 56: ...Section 3 Basic Features MC083 VCX Service Manual 56 OT 120 Terminal ...
Page 68: ...Section 4 Setup MC083 VCX Service Manual 68 EPP 6 Pump 3 1 Balancing Regulator ...
Page 80: ...Section 4 Setup MC083 VCX Service Manual 80 ...
Page 84: ...Section 6 Part Number List MC083 VCX Service Manual 84 VCX 4 Control Base 074xx042 ...
Page 86: ...Section 6 Part Number List MC083 VCX Service Manual 86 Power Supply Module 148xx063 ...
Page 97: ...MC083 VCX Service Manual Section 6 Part Number List 97 Inspection Control Module 074xx065 ...
Page 103: ...MC083 VCX Service Manual Section 6 Part Number List 103 Tracking Control Module TCMF 074xx048 ...
Page 108: ...Section 6 Part Number List MC083 VCX Service Manual 108 Junction Box 029xx439 ...
Page 110: ...Section 6 Part Number List MC083 VCX Service Manual 110 Junction Box 029xx440 ...
Page 114: ...Section 6 Part Number List MC083 VCX Service Manual 114 Standard OT 120 138xx018 ...
Page 123: ...MC083 VCX Service Manual Section 6 Part Number List 123 Scanner Cables ...
Page 126: ...Section 6 Part Number List MC083 VCX Service Manual 126 CDS Control Box 098xx102 01 ...
Page 128: ...Section 6 Part Number List MC083 VCX Service Manual 128 ...
Page 200: ...Appendix A Parameters MC083 VCX Service Manual 200 ...
Page 212: ...Appendix B Test and Diagnostic Monitor MC083 VCX Service Manual 212 ...