MC083 - VCX Service Manual
Appendix A - Parameters
171
DS-PCM4
Index
(Hex)
Sub-
Index
(Hex)
Name
Object
Type
Data
Type
Access
Type
Comment
Default
Min
Max
300D
Aux. Output
Status
VAR
U16
RW
Size = 16 bits; 0 = Off 1
= On, Bit0 = Output1,
Bit15 = Output16
0
300E
Status/Code for
Last Message
VAR
U32
RWR
Size = 4 Bytes; Bytes 0-
1 = Error/Message,
Byte2 = Error Code,
Byte3 = ErrorStatus
0
0
300F
Add. Info for
Last Message
VAR
U32
RO
Size = 4 Bytes; Bytes 0-
3 = Additional
Information for last
Error/Message
0
0
3100
Parameter
Valve Common
RECORD
Valve Common
0
Number of
Entries
VAR
U8
RO
Largest supported Sub-
index
18
1
TipSealer
Enable
VAR
U16
RW
0=Disabled, 1=Enabled
0
0
1
2
TipSealer T1
VAR
U16
RW
TipSealer Time 1 in [ms]
500
100
2000
3
TipSealer T2
VAR
U16
RW
TipSealer Time 2 in [ms]
500
100
2000
4
TipSealer T3
VAR
U16
RW
TipSealer Time 3 in [ms]
500
100
2000
5
TipSealer T4
VAR
U16
RW
TipSealer Time 4 in [ms]
500
100
2000
6
TipSealer Feed
Timeout
VAR
U16
RW
Timeout after Feedstop
in [sec]
15
5
60
7
TipSealer Feed
Polarity
VAR
U16
RW
Polarity of Feedstop
Signal
1
0
1
8
TipSealer
Pos.Switch
Enable
VAR
U16
RW
Position Switch Enabled
0
0
1
9
Copied Valve
Defaults
VAR
U16
RW
0=Valve Default
Parameters will be
copied on next power on
1=No action
0
0
1
A
Pulse Purge
Activation
VAR
U16
RW
Number of Pulses at
beginning of purge cycle
0
0
50
B
TipSealer
Status
VAR
U16
RO
TipSealer Status
0
0
255
C
TipSealer
Output Manual
VAR
U16
RW
This output is active
when the control is in the
MANUAL mode.
0 = No Output
1 = Glue Fault Light
(Blue)
2 = Jam Fault Light
(Red)
3 = Buzzer
4 = Low Level Light
(Amber)
5 = Relay 1
6 = Relay 2
0
0
6
Summary of Contents for VCX
Page 1: ...VCX Service Manual For Internal Use Only Manual Number MC083 Revision Date 5 2022 ...
Page 4: ......
Page 10: ...Section 1 Introduction MC083 VCX Service Manual 10 ...
Page 18: ...Section 2 Safety and Use MC083 VCX Service Manual 18 ...
Page 31: ...MC083 VCX Service Manual Section 3 Basic Features 31 Inspection Control Module ICM ...
Page 37: ...MC083 VCX Service Manual Section 3 Basic Features 37 Tracking Control Module TCM Cube X49 ...
Page 50: ...Section 3 Basic Features MC083 VCX Service Manual 50 Tracking Control Module TCM MARS Ejector ...
Page 56: ...Section 3 Basic Features MC083 VCX Service Manual 56 OT 120 Terminal ...
Page 68: ...Section 4 Setup MC083 VCX Service Manual 68 EPP 6 Pump 3 1 Balancing Regulator ...
Page 80: ...Section 4 Setup MC083 VCX Service Manual 80 ...
Page 84: ...Section 6 Part Number List MC083 VCX Service Manual 84 VCX 4 Control Base 074xx042 ...
Page 86: ...Section 6 Part Number List MC083 VCX Service Manual 86 Power Supply Module 148xx063 ...
Page 97: ...MC083 VCX Service Manual Section 6 Part Number List 97 Inspection Control Module 074xx065 ...
Page 103: ...MC083 VCX Service Manual Section 6 Part Number List 103 Tracking Control Module TCMF 074xx048 ...
Page 108: ...Section 6 Part Number List MC083 VCX Service Manual 108 Junction Box 029xx439 ...
Page 110: ...Section 6 Part Number List MC083 VCX Service Manual 110 Junction Box 029xx440 ...
Page 114: ...Section 6 Part Number List MC083 VCX Service Manual 114 Standard OT 120 138xx018 ...
Page 123: ...MC083 VCX Service Manual Section 6 Part Number List 123 Scanner Cables ...
Page 126: ...Section 6 Part Number List MC083 VCX Service Manual 126 CDS Control Box 098xx102 01 ...
Page 128: ...Section 6 Part Number List MC083 VCX Service Manual 128 ...
Page 200: ...Appendix A Parameters MC083 VCX Service Manual 200 ...
Page 212: ...Appendix B Test and Diagnostic Monitor MC083 VCX Service Manual 212 ...