VDF730
User
Manual
Desc
ription
of
Function
Codes
-
117
-
Function Code
Parameter
Name
Setting
Range
Default
P2
-
19
AI2
flter
time
0
.
00
–
10
.
00s
0
.
10s
The
method
of
setting
AI2
is
similar
to
that
of
setting
AI1
.
When
AI2
provides
the
current
input
,
the
current
0
–
20
mA
corresponds
to
the
voltage
0
–
10
V
.
If
the
input
current
is
4
–
20
mA
,
4
mA
corresponds
to
2
V
.
If
it
is
required
that
4
–
20
mA
corresponds
to
0
%–
100
%,
set
the
corresponding
setting
of
voltage
input
to
2
–
10
V
.
Note
that
P2
-
11
and
P2
-
17
must
not
be
set
to
1
at
the
same
time
.
Otherwise
,
AI1
and
AI2
will
become
invalid
due
to
the
setting
confict
.
Function
Code
Parameter
Name
Setting
Range
Default
P2
-
20
Pulse
minimum
input
0
.
00
kHz
to
P2
-
22
0
.
00
kHz
P2
-
21
Corresponding
setting
of
pulse
minimum
input
-
100
.
00
%–
100
.
0
%
0
.
0
%
P2
-
22
Pulse
maximum
input
P2
-
20
to
50
.
00
kHz
50
.
00
kHz
P2
-
23
Corresponding
setting
mode
of
pulse
maximum
input
0
:
P2
-
24
1
:
Determined
by
AI1
2
:
Determined
by
AI2
0
P2
-
24
Corresponding
setting
of
pulse
maximum
input
-
100
.
00
%–
100
.
0
%
100
.
0
%
P2
-
25
Pulse
flter
time
0
.
00
–
10
.
00s
0
.
10s
These parameters are used to set the relationship between DI5 pulse input and
corresponding settings
.
The pulses can only be input by DI5
.
The method of setting this
function
is
similar
to
that
of
setting
AI1
function
.
Note that when P0
-
01 is
set to 3
(
Pulse
setting
),
P3
-
00 must not be set to 0
(
FMP pulse
output
),
and
vice
versa
.
Function
Code
Parameter
Name
Setting
Range
Default
P2
-
26
DI
valid
state
selection
0
–
127
0
This
parameter
defnes
the
valid
state
of
DI
terminals
by
bit
.
•
0
:
Positive
logic
The terminal is valid when being connected with COM
,
and invalid when being
disconnected
from
COM
.
•
1
:
Negative
logic
The
terminal
is
invalid
when
being
connected
with
COM
,
and
valid
when
being
disconnected
from
COM
.
Bit
BIT6
BIT5
BIT4
BIT3
BIT2
BIT1
BIT0
Terminal
AI2
AI1
DI5
DI4
DI3
DI2
DI1
To
set
a
DI
as
the
negative
logic
,
set
the
corresponding
bit
to
1
,
convert
the
binary
value
to
a
decimal
value
,
and
then
set
the
decimal
value
in
this
function
code
.
Summary of Contents for VDF730 Series
Page 1: ...VDF730 Series...
Page 7: ......
Page 8: ...1 Safety Information and Precautions...
Page 15: ...Safety Information and Precautions VDF730 User Manual 14...
Page 16: ...2 Product Information...
Page 30: ...3 Mechanical and Electrical Installation...
Page 51: ...Mechanical and Electrical Installation VDF730 User Manual 50...
Page 52: ...4 Operation and Display...
Page 75: ...Operation and Display VDF730 User Manual 74...
Page 76: ...5 Function Code Table...
Page 97: ...Function Code Table VDF730 User Manual 96...
Page 98: ...6 Description of Function Codes...
Page 153: ...Description of Function Codes VDF730 User Manual 152...
Page 154: ...7 EMC...
Page 158: ...8 Troubleshooting...