Description
of
Function
Codes
VDF730
User
Manual
-
108
-
Function
Code
Parameter
Name
Setting
Range
Default
P1
-
13
Slip
compensation
coeffcient
0
%–
200
.
0
%
0
.
0
%
It
can
compensate
the
rotational
speed
slip
of
the
asynchronous
motor
when
the
load
of
the
motor
increases
,
stabilizing
the
motor
speed
in
case
of
load
change
.
If this
parameter
is
set to 100
%,
it
indicates
that
the
compensation
when the
motor
bears
rated
load
is
the
rated
motor
slip
.
When
the
motor
bears
the
rated
load
and
this
parameter
is
set
to
100
%,
the
rotational
speed
of
the
motor
is
close
to
the
set
speed
.
Modify
this
parameter
based
on
such
a
principle
.
Before
performing
automatic
torque
boost
or
slip
compensation
,
carry
out
motor
auto
-
tuning
to
guarantee
the
control
effect
.
Follow
the
precautions
:
•
When this parameter is set to a large value
,
the motor may oscillate
.
In this case
,
decrease
the
value
of
this
parameter
.
•
Do
not
use
the
automatic
torque
boost
and
slip
compensation
functions
simultaneously
.
Function
Code
Parameter
Name
Setting
Range
Default
P1
-
14
Over
-
excitation
gain
0
–
200
64
During deceleration of the AC drive
,
over
-
excitation can restrain rise of the bus voltage
,
preventing
the
overvoltage
fault
.
The
larger
the
over
-
excitation
is
,
the
better
the
restraining
result
is
.
Set the
over
-
excitation
gain to
0 in
the
applications where
the
inertia
is
small
and
the
bus
voltage
will
not
rise
during
motor
deceleration
or
where
there
is
a
braking
resistor
.
Increase
the
over
-
excitation
gain
properly
when
the
inertia
is
large
.
Function
Code
Parameter
Name
Setting
Range
Default
P1
-
15
No
-
load
current
0
.
1
A
to
P1
-
02
Model
dependent
P1
-
16
Stator
resistance
0
.
001
–
65
.
535
Ω
Model
dependent
Set these parameters based on the motor parameters
.
If these parameters are set
incorrectly
,
the control performance will be affected
.
If you are sure about the values
,
perform
motor
auto
-
tuning
,
or
contact
the
manufacturer
of
the
motor
.
Function
Code
Parameter
Name
Setting
Range
Default
P1
-
17
Oscillation
suppression
gain
0
–
100
Model
dependent
Set
this
parameter
to
a
value
as
small
as
possible
in
the
prerequisite
of
effcient
oscillation
suppression
to
avoid
infuence
on
V
/
F
control
.
Set this parameter to 0 if the motor has no oscillation
.
Increase the value properly only
when the motor has obvious oscillation
.
The larger
the value is
,
the better
the oscillation
suppression
result
will
be
.
When the oscillation suppression function is enabled
,
the rated motor current and no
-
load
current
must
be correct
.
Otherwise
,
the V
/
F
oscillation
suppression
effect
will
not be
satisfactory
.
Summary of Contents for VDF730 Series
Page 1: ...VDF730 Series...
Page 7: ......
Page 8: ...1 Safety Information and Precautions...
Page 15: ...Safety Information and Precautions VDF730 User Manual 14...
Page 16: ...2 Product Information...
Page 30: ...3 Mechanical and Electrical Installation...
Page 51: ...Mechanical and Electrical Installation VDF730 User Manual 50...
Page 52: ...4 Operation and Display...
Page 75: ...Operation and Display VDF730 User Manual 74...
Page 76: ...5 Function Code Table...
Page 97: ...Function Code Table VDF730 User Manual 96...
Page 98: ...6 Description of Function Codes...
Page 153: ...Description of Function Codes VDF730 User Manual 152...
Page 154: ...7 EMC...
Page 158: ...8 Troubleshooting...