COMMISSIONING
64
NOTICE!
►
Tightening torque M6 = 7 Nm. Standard cable
outlet on left, right also possible.
Step 3
Assembly steps:
1. Place the cover cap on the conductor rail and pay
attention to cable routing.
Step 4
Assembly steps:
1. The cable outlet is at the side (left or right) of the
cable connection.
TIPS AND RECOMMENDATIONS!
The connecting cables for the VLS line feeds can also
be supplied pre-assembled (preferably rubber hose
line HO7RN-F/H07V-K).
Line feed VNS
Step 1
Required tools:
⚒
Screwdriver
⚒
Torque wrench
Assembly steps:
1. Open the cover on the installed line feed
2. Strip and cut the connecting wires as required.
3. Attach the cable lugs to the single wires and pass
the connecting cable through the cable gland.
4. Screw the cable lugs to the connecting pins with
the hexagon screws (M10, M5), lock washers and
hexagon nuts.