7.5.2
Device - Tramline motor and tramline monitoring
Cabling:
Tramline motor and tramline detector
7.5.3
Device - Level guard
Cabling:
Detector:
Table 7.7 Configuration - Tramline motor and tramline monitoring
Connector pole Cabling pole left Function
1
12
Tramlining off
2
13
Tramlining on
3
5
Ground
4
19
Signal
5
36
+12V
6
5
Ground
Table 7.8 Configuration
Connector pole Cable - Colour Function
1
Motor - Green
Tramlining off
2
Motor - Black
Tramlining on
3
Motor - Blue
Ground
4
Detector - Black
Signal from tramline detector
5
Detector - Brown
+12V
6
Detector - Blue
Ground
Table 7.9 Level guard configuration
Connector pole Cabling pole Cable colour Function
1
16
Orange
Signal
2
36
Brown
+12V
3
5
Blue
Ground
Table 7.10 Detector configuration
Connector pole Cable colour Function
1
White
Signal
2
Brown
+12V
3
Blue
Ground