RD 300-450 F
Ver.1.3 07/06/01
111
7.5
Connector, mftg. no. 10950 -
7.5.1
Device - Tachometer for fan and area meter
Cabling:
Detector:
Table 7.4 Fan detector configuration
Connector pole Cabling pole Cable colour Function
1
24
Grey
Signal
2
36
Brown
+12V
3
5
Blue
Ground
Table 7.5 Area meter configuration
Connector pole Cabling pole Cable colour Function
1
20
Green
Signal
2
36
Brown
+12V
3
5
Blue
Ground
Table 7.6 Detector configuration
Connector pole Cable colour Function
1
Black
Signal
2
Brown
+12V
3
Blue
Ground