5
5.10 Digital outputs (Control panel: Menu PAR -> P8)
Code
Parameter
Min
Max
Unit Default
ID
Selections
P8.1
RO1 signal
selection
0
Varies
2
313
0
= Not used
1
= Ready
2
= Run
3
= Fault
4
= Fault Inverted
5
= Warning
6
= Reversed
7
= At Speed
8
= Motor regulator active
9
= FB Control Word B13
10
= FB Control Word B14
11
= FB Control Word B15
12
= Output freq superv
13
= Output torque superv
14
= Unit temperature superv
15
= Analog input superv
16
= Preset Speed Active
17
= External Brake Ctrl
18
= Keypad control active
19
= I/O control active
20 =
Temperature supervision
P8.2
RO2 signal
selection
0
Varies
3
314 See 8.1
P8.3
DO1 signal
selection
0
Varies
1
312 See 8.1
P8.4
RO2 inversion
0
1
0
1588
0
= No inversion
1
= Inverted
P8.5
RO2 ON delay
0.00
320.00
s
0.00
460 0.00 = No delay
P8.6
RO2 OFF delay
0.00
320.00
s
0.00
461 0.00 = No delay
P8.7
RO1 inversion
0
1
0
1587
0
= No inversion
1
= Inverted
P8.8
RO1 ON delay
0.00
320.00
s
0.00
458 0.00 = No delay
P8.9
RO1 OFF delay
0.00
320.00
s
0.00
459 0.00 = No delay
P8.10
DOE1 signal
selection
0
Varies
0
317
See 8.1, hidden until an
option board is connected
P8.11
DOE2 signal
selection
0
Varies
0
318
See 8.1, hidden until an
option board is connected
P8.12
DOE3 signal
selection
0
Varies
0
1386
See 8.1, hidden until an
option board is connected
Table 10: Digital outputs