ENGLISH
- 56 -
PARAMETER
VALUE
DESCRIPTION
DEFAULT
MEMO
SEnS
Enable the obstacle sensor
no
1.0A - 10.0A
This menu allows you to regulate the sensitivity of the obstacle sensor.
When the current absorbed by the motor exceeds the set value, the
controller detects an alarm.
During the opening, an obstacle would cause the arrest of the boom.
During the closing, an obstacle would cause the complete reopening, in
order to free the obstacle.
In both cases the automatic closing comes disabled the second time that
the cycle is interrupted by an obstacle.
If the obstacle is found nearing the of the travel height, is interpreted as a
mechanical arrest
no
Function deactivated
rA.AP
Slow down in opening
25
0 - 1 00
This menu allows regulating the percentage of the ride/drive that is carried
out at reduced speed during the last opening stretch
rA.Ch
Slow down in closing
25
0 - 1 00
This menu allows regulating the percentage of the ride/drive that is carried
out at reduced speed during the last closing stretch.
St .AP
Start command during the opening phase
This menu allows fixing the control unit conduct in case it receives a Start
command during the opening phase.
PAUS
PAUS
The barrier closes and enters in pause
ChiU
The barrier immediately starts to reclose
no
The barrier continues to open (the command is ignored)
St .Ch
Start command during the closing phase
This menu allows fixing the control unit conduct in case it receives a Start
command during the closing phase
StoP
StoP
The barrier closes and the cycle is considered concluded
APEr
The barrier reopens
St .PA
Start command during the pause
This menu allows establishing the behavior of the control units if a Start
command is received while the barrier is opened in pause.
ChiU
ChiU
The barrier starts to reclose
no
The command is ignored
PAUS
The pause time becomes recharged (
Ch.AU
)
Ch.AU
Automatic Closing
In automatic operation, the control unit automatically recloses the barrier
at the end of the preset time
no
no
Function deactivated
0.5” - 20’0
The barrier recloses after the time set
Summary of Contents for NIUBA-24V
Page 2: ...1153 mm 320 mm 287 mm 218 mm 897 mm 1168 mm 374 mm 239 mm 319 mm 897 mm ...
Page 7: ...ITALIANO 5 NIUBA4 NIUBA6 ...
Page 11: ...ITALIANO 9 FIG 3 FIG 4 ...
Page 13: ...ITALIANO 11 A D E C F F G E A B D C O N M ...
Page 31: ...ITALIANO 29 ...
Page 34: ...ITALIANO 32 ...
Page 39: ...ENGLISH 37 NIUBA4 NIUBA6 ...
Page 43: ...ENGLISH 41 FIG 3 FIG 4 ...
Page 45: ...ENGLISH 43 A D E C F F G E A B D C O N M ...
Page 63: ...ENGLISH 61 ...
Page 66: ...ENGLISH 64 ...
Page 71: ...FRANÇAIS 69 NIUBA4 NIUBA6 ...
Page 75: ...FRANÇAIS 73 FIG 3 FIG 4 ...
Page 77: ...FRANÇAIS 75 A D E C F F G E A B D C O N M ...
Page 95: ...FRANÇAIS 93 ...
Page 98: ...FRANÇAIS 96 ...
Page 103: ...ESPAÑOL 101 NIUBA4 NIUBA6 ...
Page 107: ...ESPAÑOL 105 FIG 3 FIG 4 ...
Page 109: ...ESPAÑOL 107 A D E C F F G E A B D C O N M ...
Page 127: ...ESPAÑOL 125 ...
Page 130: ...ESPAÑOL 128 ...
Page 131: ......