ENGLISH
- 36 -
1.2 - TECHNICAL ASSISTANCE SERVICE
For any installation problem please contact our Customer Service
at the 39-0172.812411 operating Monday to Friday
from 8:30 to 12:30 and from 14:00 to 18:00.
1.3 - EU DECLARATION OF
CONFORMITY AND DECLARATION
OF INCORPORATION OF PARTLY
COMPLETED MACHINE
Declaration in accordance with Directives: 2014/35/UE (LVD);
2014/30/UE (EMC); 2006/42/CE (MD) ANNEX II, PART B
The manufacturer V2 S.p.A., headquarters in Corso Principi di
Piemonte 65, 12035, Racconigi (CN), Italy
Under its sole responsibility hereby declares that:
the partly completed machinery model(s):
NIUBA4-24V, NIUBA6-24V
NIUBA4-24V-120V, NIUBA6-24V-120V
Description: electromechanical actuator for barriers
• is intended to be installed to create a machine according to
the provisions of the Directive 2006/42/EC. The machinery
must not be put into service until the final machinery
into which it has to be incorporated has been declared in
conformity with the provisions of the Directive 2006/42/EC
(annex II-A).
• is compliant with the applicable essential safety requirements
of the following Directives:
Machinery Directive 2006/42/EC (annex I, chapter 1)
Low Voltage Directive 2014/35/EU
Electromagnetic Compatibility Directive 2014/30/EU
Directive ROHS2 2011/65/CE
The relevant technical documentation is available at the national
authorities’ request after justifiable request to:
V2 S.p.A.
Corso Principi di Piemonte 65, 12035, Racconigi (CN), Italy
The person empowered to draw up the declaration and to provide
the technical documentation:
Sergio Biancheri
Legal representative of V2 S.p.A.
Racconigi, il 01/06/2019
2 - TECHNICAL CHARACTERISTICS
NIUBA4-24V
NIUBA6-24V
Power supply
230 V~ 50 Hz
Motor power
supply
24 Vdc
Maximum power
240W
300W
Power in stand-by
3,5W
3,5W
Opening time
3 ÷ 4 s
5 ÷ 6 s
Operative
intermittence
80 %
(200 cicli ora max.)
80 %
(150 cicli ora max.)
Maximum load on
24 Vdc attachments
12W
(acces flashing light + holding
magnet)
Operating
temperature
-20 ÷ +55 °C
Protection degree
IP44
Weight
44 Kg
52 Kg
NIUBA4-24V-120V NIUBA6-24V-120V
Power supply
120 V~ 60 Hz
Motor power
supply
24 Vdc
Maximum power
240W
300W
Power in stand-by
3,5W
3,5W
Opening time
3 ÷ 4 s
5 ÷ 6 s
Operative
intermittence
80 %
(200 cicli ora max.)
80 %
(150 cicli ora max.)
Maximum load on
24 Vdc attachments
12W
(acces flashing light + holding
magnet)
Operating
temperature
-20 ÷ +55 °C
Protection degree
IP44
Weight
44 Kg
52 Kg
Summary of Contents for NIUBA-24V
Page 2: ...1153 mm 320 mm 287 mm 218 mm 897 mm 1168 mm 374 mm 239 mm 319 mm 897 mm ...
Page 7: ...ITALIANO 5 NIUBA4 NIUBA6 ...
Page 11: ...ITALIANO 9 FIG 3 FIG 4 ...
Page 13: ...ITALIANO 11 A D E C F F G E A B D C O N M ...
Page 31: ...ITALIANO 29 ...
Page 34: ...ITALIANO 32 ...
Page 39: ...ENGLISH 37 NIUBA4 NIUBA6 ...
Page 43: ...ENGLISH 41 FIG 3 FIG 4 ...
Page 45: ...ENGLISH 43 A D E C F F G E A B D C O N M ...
Page 63: ...ENGLISH 61 ...
Page 66: ...ENGLISH 64 ...
Page 71: ...FRANÇAIS 69 NIUBA4 NIUBA6 ...
Page 75: ...FRANÇAIS 73 FIG 3 FIG 4 ...
Page 77: ...FRANÇAIS 75 A D E C F F G E A B D C O N M ...
Page 95: ...FRANÇAIS 93 ...
Page 98: ...FRANÇAIS 96 ...
Page 103: ...ESPAÑOL 101 NIUBA4 NIUBA6 ...
Page 107: ...ESPAÑOL 105 FIG 3 FIG 4 ...
Page 109: ...ESPAÑOL 107 A D E C F F G E A B D C O N M ...
Page 127: ...ESPAÑOL 125 ...
Page 130: ...ESPAÑOL 128 ...
Page 131: ......