Default Setting (System Menu)
8-78
3
Press [IPP over SSL Only] or [IPP or IPP over SSL].
4
Press [OK].
5
After changing the setting, restart the system or turn the machine OFF and then ON again.
For detailed information on restarting the system, refer to
Restarting the System on page 8-72
.
HTTP Security Setup
Select the HTTP security level. This setup is available when
SSL
is
On
. The default setting is
HTTPS Only
.
NOTE:
HTTP must be set to [On] in
Protocol Detail on page 8-75
.
Use the procedure below.
1
Press the
System Menu
key.
2
Press [System], [Next] of
Network
, [Next] of
Secure Protocol
, and then [Change] of
HTTPS Security
.
3
Press [HTTP or HTTPS] or [HTTPS Only].
4
Press [OK].
5
After changing the setting, restart the system or turn the machine OFF and then ON again.
For detailed information on restarting the system, refer to
Restarting the System on page 8-72
.
LDAP Security Setup
Select the type of encryption according to the type of security employed by the LDAP server. This setup is
available when
SSL
is
On
. The default setting is
Off.
NOTE:
LDAP must be set to [On] in
Protocol Detail on page 8-75
.
The table below shows the available settings.
Use the procedure below.
1
Press the
System Menu
key.
2
Press [System], [Next] of
Network
, [Next] of
Secure Protocol
, and then [Change] of
LDAP Security
.
3
Press [Off], [LDAP over SSL] or [LDAPv3/TLS].
Item
Description
Off
Do not use security employed by the LDAP server.
LDAP over SSL
Use implicit mode for data communication. The server provides services
using the LDAP over SSL port (636). Encryption is applied to any data
communication using this port.
LDAPv3/TLS
Use explicit mode for data communication. Select this if the server supports
the start TLS command. This uses the same port (389) as LDAP.
Summary of Contents for CDC 1725
Page 1: ...Instruction Handbook Digital Multifunctional System CDC 1725 1730 1740 1840 1850 ...
Page 20: ...xviii ...
Page 72: ...Preparation before Use 2 36 ...
Page 168: ...Copying Functions 4 46 ...
Page 394: ...Management 11 28 ...
Page 397: ...Appendix 3 Key Counter FAX Kit Expansion Memory ...
Page 436: ...UTAX GmbH Ohechaussee 235 22848 Norderstedt Germany ...