3N0/3NK/3PD/3PG
1-4-5
5011
Bridge conveying sensor 2
stay jam
The bridge conveying sensor 2(BRCS2) does not
turn off during paper feed from cassette 1.
I
5012
The bridge conveying sensor 2(BRCS2) does not
turn off during paper feed from cassette 2.
I
5013
The bridge conveying sensor 2(BRCS2) does not
turn off during paper feed from cassette 3.
I
5014
The bridge conveying sensor 2(BRCS2) does not
turn off during paper feed from cassette 4.
I
5018
The bridge conveying sensor 2(BRCS2) does not
turn off during paper feed from duplex section.
I
5019
The bridge conveying sensor 2(BRCS2) does not
turn off during paper feed from the MP tray.
I
6000
DF paper entry error
DF paper entry sensor (DFPES) turns on before
the eject signal is output from the machine.
-
6020
DF front cover open
DF front upper cover is opened during operation.
-
6060
MB cover open
MB cover is opened during operation.
-
6100
DF paper entry sensor non
arrival jam
DF paper entry sensor (DFPES) does not turned
on even if a specified time has elapsed after the
machine eject signal was received.
I
6110
DF paper entry sensor stay
jam
DF paper entry sensor (DFPES) does not turned
off within specified time of its turning on.
J
6200
DF sub eject sensor non
arrival jam
DF sub eject sensor (DFSES) does not turn on
within specified time of DF paper entry sensor
(DFPES) turning on.
J
6210
DF sub eject sensor stay jam DF sub eject sensor (DFSES) does not turned off
within specified time of its turning on.
J
6300
DF middle eject sensor non
arrival jam
DF middle eject sensor (DFMES) does not turn on
within specified time of DF paper entry sensor
(DFPES) turning on.
J
6310
DF middle eject sensor stay
jam
DF middle eject sensor (DFMES) is not turned off
within specified time of its turning on.
J
6400
DF tray upper surface sen-
sor non arrival jam
DF tray upper surface sensor (DFTUSS) does not
turn on within specified time of DF middle eject
sensor (DFMES) turning on.
J
6410
DF tray upper surface sen-
sor stay jam
DF tray upper surface sensor (DFTUSS) is not
turned off within specified time of its turning on.
J
6500
DF eject paper sensor non
arrival jam
DF bundle discharge sensor (DFBDS) does not
turn on within specified time of DF middle eject
sensor (DFMES) turning on.
J
6510
DF eject paper sensor stay
jam
DF bundle discharge sensor (DFBDS) is not turned
off since the bundle discharge starts.
J
Code
Contents
Conditions
Jam
location*
*: Refer to figure 1-4-1 for paper jam location (see page 1-4-1).
Summary of Contents for AK 740
Page 1: ...Service Manual RFXPHQW LQLVKHU D 07 3 LUVW GLWLRQ Date 2 0 20 3 SM06 ...
Page 2: ...Service Manual RFXPHQW LQLVKHU D 07 3 LUVW GLWLRQ Date 2 0 20 3 SM06 ...
Page 4: ...Revision history Revision Date Pages Revised contents ...
Page 5: ...This page is intentionally left blank ...
Page 11: ...This page is intentionally left blank ...
Page 17: ...3N0 3NK 3PD 3PG 1 1 4 2 Mail box option Figure 1 1 2 1 2 1 Trays 1 7 2 Mailbox cover ...
Page 29: ...3N0 3NK 3PD 3PG 1 2 10 This page is intentionally left blank ...
Page 45: ...3N0 3NK 3PD 3PG 1 3 16 This page is intentionally left blank ...
Page 129: ...3N0 3NK 3PD 3PG 2 2 9 This page is intentionally left blank ...
Page 155: ...1 1 INSTALLATION GUIDE DF 791 3000 sheet finisher Installation Guide ...
Page 170: ...AK 740 Bridge unit Installation Guide ...
Page 172: ...MT 730 B Mail box Installation Guide ...