28
Infusion Carbon Filter Valve Battery Backup
Battery Back
-
Up
(Uses a standard 9
-
volt alkaline battery.)
•
During power failures, the battery will maintain the time of day as long as the battery has pow-
er. The display is turned off to conserve battery power during this time. To confirm that the bat-
tery is working, press either button and the display will turn on for five (5) seconds.
•
If power failure occurs while system is regenerating, the Signature 2 will motor to a shut off
position to prevent constant flow to drain. Depending upon system pressure and other factors,
it is possible to observe a reduced flow to drain during this step. After power is restored, the
Signature 2 will return and finish the cycle where it left off prior to the power interruption.
•
When used without battery back
-
up, during a power failure, the unit stops at its current point
in the regeneration position and then restarts at that point when the power is restored. The time
will be offset by the increment of time the unit was without power, so it is necessary to reset the
time of day on the unit. No other system will be affected.
WARNING!
DO NOT INSTALL THE BATTERY BACKUP UNTIL THE SYSTEM HAS BEEN
PROGRAMMED AND START UP IS COMPLETE!
1.
Remove the two screws on the back of the valve.
2.
Pull out the 9V battery connector, remove battery cover
and attach the batter to the connector.
3.
Push the batter back in the holder on the valve and re-
place the cover and screws.