Page 1: ...1 DIGITAL CALL SYSTEM...

Page 2: ...http www miwiurmet com pl e mail miwi miwiurmet com pl 2...

Page 3: ...31 520 52 HOUSE PHONE WITH ADDITIONAL BUTTON REF 1131 521 53 TABLE TOP MOUNTING KIT REF 1130 120 53 HOUSE PHONE REF 1132 520 54 HOUSE PHONE WITH ADDITIONAL BUTTON REF 1131 521 55 TABLE TOP MOUNTING KI...

Page 4: ......

Page 5: ...y and ventilated places it is recommended that it is assembled in special boxes designed for this purpose Equipment should be separated from the electrical telephone and antenna installations WIRES A...

Page 6: ...onnection one entrance panel and max 510 door phones using two risers in the power unit INSTALATION WITH SEVERAL MAIN ENTRANCE PANELS Connection up to 240 entrance panels and max 510 door phones using...

Page 7: ...ANEL Connection one entrance panel and max 127 video door phones using one riser in the power unit or 254 video doorphones using two risers in the power unit VIDEO DOORPHONE INSTALATION WITH SEVERAL E...

Page 8: ...x width x deep 152 x 110 x 23 35mm ref no 1052 10D Size high x width x deep 175 x 135 x 23 6mm with frame 525 RP2 CALL MODULE WITH KEYBOARD REF 1052 11 11D BASIC FEATURES Digital call module with keyb...

Page 9: ...width x deep 152 x 110 x 23 35mm ref no 1052 10D Size high x width x deep 175 x 135 x 23 6mm with frame 525 RP2 CALL MODULE WITH KEYBOARD REF 1052 16 16D BASIC FEATURES Digital call module with keyboa...

Page 10: ...e In order to increase number of user codes automatically change parameters in steps 7 4 and 7 5 and generate new individual opening user codes by step 4 4 SIGNALING OF DOOR LOCK AND NO NC RELEASING I...

Page 11: ...a button which performs this function FUNCTION OF TERMINAL R The Matibus SE call module is equipped with terminal R which is output in the form of open collector From the start of conversation till t...

Page 12: ...6 Call module software version P 7 X X Advanced functions 0 0 Keyboard backlight adjustment 0 1 Switch on switchboard 0 2 Programming number of keyboard uniting logical entry EXI with EO of power supp...

Page 13: ...the house phone when individual opening code associated with that house phone was used We can choose 0 Turn off confirmation of opening the door and exit NC C NO 1 Turn on confirmation of opening the...

Page 14: ...or phone line 1 7V door phone line To save entered changes press Default settings 1 2 TIME SETTINGS 2 01 ELECTRICAL LOCK TIME OF WORKING P 2 0 1 After pressed the button on the LED display will be sho...

Page 15: ...be shown this communication 3 04 DELETING ALL LOGICAL USER CODE MASTER P 3 0 4 To activate this function please press button During this process on LED display will be shown this communication 3 05 D...

Page 16: ...store times Advanced functions To activate this function please press button During this process on LED display will be shown this communication 5 LOGICAL USER AND OPENING CODES 5 01 LOGICAL USER CODE...

Page 17: ...ation o o o o If logical code is already associated with some opening code this opening code will be shown on the LED display Than you should Enter 4 digits number of new code or leave previous one Co...

Page 18: ...key or press button to exit 5 07 DALLAS KEY IDENTIFICATION This step allows you to identify Dallas key P 5 0 7 Pressing the button on the LED will be shown this communication In order to identify Dall...

Page 19: ...creen will be shown less significant part of the software version for example software for call module serial number of software 0718 the LED display will show L 7 1 8 Another pressing the button will...

Page 20: ...s connected to call module by terminals CL CL These terminals are able to service electric door lock for DC and AC voltage Parameter which we will choose in this part of the programming mode set the f...

Page 21: ...ical code of the house phone Confirm by pressing button If the physical code was not associated with any logical user code the LED displays this communication L L L L If physical code has been already...

Page 22: ...LED appears dots To save new parameter press button Default settings 0 9 FEATURES THAT IMPROVE 9 01 DEACTIVATION OFF INFORMATION P 9 0 1 This step allows you to deactivate displaying OFF information i...

Page 23: ...exing additional ringback tone on the house phone while waiting for pick up the handy pickup time We are able to set 0 OFF 1 ON Press button to save parameter Default settings 1 9 07 AUTOMATIC CHOOSIN...

Page 24: ...ct physical code E r 1 0 Inactivity time too long in programming mode E r 1 1 Several door phones with the same address E r 1 2 Dallas key already assigned E r 1 3 EEPROM full Lack of communication be...

Page 25: ...light on the LED display should appear blinking dot In case of lack of backlight check connection and installation check terminal voltage AC1 and AC2 Communication checking The best way to check commu...

Page 26: ...of the case 8 Press down part of the PCB assembly kit 9 Connect the wires 10 Connect terminal X2 speaker and X10 Dallas key reader Fig 2 11 Close and fasten the front panel Fig 2 PCB assembly kit FLU...

Page 27: ...ssembly kit into latches located in the top part of the case 11 Press down part of the PCB assembly kit 12 Connect the wires 13 Connect terminal X2 speaker X10 Dallas key reader and X12 backlight info...

Page 28: ...klight information module It enables you to put a list of tenants This panel is characterized by a high degree of protection from acts of vandalism CALL MODULE WITH KEYBOARD AND CAMERA REF 1752 16 16D...

Page 29: ...V AC CL Electric lock output CL Electric lock output NC Relay normally closed contact C Relay Common contact NO Relay normally open contact PH Door lock release GND Contacts input output ground EXI Co...

Page 30: ...it into latches located in the top part of the case 11 Press down part of the PCB assembly kit 12 Connect the wires 13 Connect terminal X2 speaker X10 Dallas key reader and X12 backlight information p...

Page 31: ...MOUNTING PANELS 1752 11 AND 1752 16 http www miwiurmet com pl e mail miwi miwiurmet com pl 31 Fig 9...

Page 32: ...utton in the house phone 5 Open door input 6 Exit dedicated to handling video 7 Hall button timed input 8 Programmable system 9 System information shown on LED display STRUCTURE Call module is based o...

Page 33: ...to 4 long and in range from 1 9999 These users codes logic codes are associated with the house phones codes physical codes Every house phone has unique code depending of the number of riser and of th...

Page 34: ...terminal PH which is performing for local opening door Connection PH and GND lead to turn on electric lock for programmed time To implement this function during the installation between terminals PH...

Page 35: ...ll module software version P 7 X X Advanced functions 0 0 Keyboard backlight adjustment 0 1 Switch on switchboard 0 2 Programming number of keyboard uniting logical entry EXI with EO of power supply i...

Page 36: ...n the house phone when individual opening code associated with that house phone was used We can choose 0 Turn off confirmation of opening the door and exit NC C NO 1 Turn on confirmation of opening th...

Page 37: ...ORKING P 2 0 1 After pressed the button on the LED display will be shown actual programmed time in seconds To confirm that time press button or enter number of seconds from 1 to 30s To save entered ch...

Page 38: ...LL DALLAS KEYS P 3 0 5 To activate this function please press button During this process on LED display will be shown this communication 3 06 DELETING ALL DIGITISER DATA P 3 0 6 To activate this funct...

Page 39: ...gic user code can be associated to every physicla user code set in the house phone physical code To do it Enter the number of riser to which house phone is connected Enter physical code of the house p...

Page 40: ...G P 5 0 4 You can program 64 general opening codes with the possibility of individual assignment to specific keyboard The maximum number of codes is constant for the MASTER power supply which means in...

Page 41: ...generate warning signal Press button to exit 6 SERVICE FUNCTIONS 6 01 SERIAL NUMBER OF THE POWE SUPPLY P 6 0 1 Entering in to this function we are able to get known serial number of the Power supply s...

Page 42: ...y will show L 7 1 8 Another pressing the button will shown the rest part of the version of software for call module serial number of software 0718 the LED display will show H 0 7 ADVANCED FUNCTIONS 7...

Page 43: ...his step we are programming frequency of electric door lock mode which is connected to call module by terminals CL CL These terminals are able to service electric door lock for DC and AC voltage Param...

Page 44: ...umpers set in the house phone physical code To do it Enter the number of riser to which house phone is connected Enter physical code of the house phone Confirm by pressing the button If the physical c...

Page 45: ...oards 255 no keyboard In this step on LED appears dots To save new parameter press button Default settings 0 9 FEATURES THAT IMPROVE 9 01 DEACTIVATION OFF INFORMATION P 9 0 1 This step allows you to d...

Page 46: ...tone on the house phone while waiting for pick up the handy pickup time We are able to set 0 OFF 1 ON Press button to save parameter Default settings 1 9 07 AUTOMATIC CHOOSING OF MASTER POWER SUPPLY...

Page 47: ...without assigned Dallas key E r 0 9 Incorrect physical code E r 1 0 Inactivity time too long in programming mode E r 1 1 Several door phones with the same address E r 1 2 Dallas key already assigned E...

Page 48: ...ght on the LED display should appear blinking dot In case of lack of backlight check connection and installation check terminal voltage AC1 and AC2 Communication checking The best way to check communi...

Page 49: ...height of approximately 1 55 1 60 meters Important The module should not be illuminated from behind to make the calling module display easier to read Never direct the module towards strong sources of...

Page 50: ...rame screw last FLUSH MOUNTED VERSION WITH RAIN HOOD Rain hoods are used to protect the calling module from the weather Embed the flush mounting box in the wall position the waterproof hood and fasten...

Page 51: ...INSTALLATION http www miwiurmet com pl e mail miwi miwiurmet com pl 51...

Page 52: ...mber 1 We use only first 8 jumpers from right and the other two are used for testing house phone Number of house phone is set in binary code as described on the PCB Each jumper founded increases the n...

Page 53: ...itting other 3 supplementary buttons Additional button can be used for calling switchboard control NO NC relay etc Additional button is connected with terminals T1 and L and serves to control power su...

Page 54: ...1 We use only first 8 jumpers from right and the other two are used for testing house phone Number of house phone is set in binary code as described on the PCB Each jumper founded increases the numbe...

Page 55: ...fitting other 6 supplementary buttons Additional button can be used for calling switchboard control NO NC relay etc Additional button is connected with terminals T1 and L and serves to control power s...

Page 56: ...physical address is set with jumpers We can set the phone number from 1 to 255 The first jumper from right is the number 1 We use only first 8 jumpers from right and the other two are used for testin...

Page 57: ...rovided with additional button and ready for fitting other 6 supplementary buttons Additional button can be used for calling switchboard control NO NC relay etc Additional button is connected with ter...

Page 58: ...an be installed on the wall without the need of forging the wall The Winflat has adjustable call tone volume brightness and contrast The Winflat is provided with 2 supplementary buttons for activating...

Page 59: ...F button implement video auto on function S3 button configuration Service button active Floor call terminals Y1 Y2 active S4 button configuration Service button active UTP S5 Kind of video line COAX P...

Page 60: ...ut for external bell push Connection Y1 and Y2 together will be activated floor call ring in the video door phone SELECTING CALLING TONE The bracket is equipped with 3 calling tones To select calling...

Page 61: ...ND EI Entry control relay or electrical lock 0L GND for riser 2 LU2 Riser 2 0L GND for riser 1 LU1 Riser 1 DIAGNOSTIC Two LED indicate the status of the power supply The illumination of a green LED in...

Page 62: ...door output 0L GND EI Entry control relay or electrical lock 0L GND for riser 2 LU2 Riser 2 0L GND for riser 1 LU1 Riser 1 DIAGNOSTIC Two LEDs indicate the status of the power supply The illumination...

Page 63: ...AC Power 20 VA Output voltage 0 20 20 V DC 0 8 A max Operating temperature 5 C 45 C Protectio Fuse 100mA Dimensions Length 126 mm 7 DIN Width 90 mm Deep 75 mm VIDEO POWER SUPPLY REF 789 7P BASIC FEAT...

Page 64: ...butor 1 Press PROG button 2 Red LED will turn on 3 Make a call to one of the monitor connected to relevant distributor 4 Wait until camera s image appears and disconnect conversation One of the distri...

Page 65: ...vided with 4 independent outputs plus one through output DESCRIPTION OF TERMINALS R1 Power input gnd R2 Power input positive E Coax input U1 U5 Coax output Remove jumper JP1 in the video distributor t...

Page 66: ...equipped with 4 relay outputs one of them is dedicated for COAX cable DESCRIPTION OF TERMINALS Ra Relay control input Rb Relay control input 12 Power voltage 12 V DC 24 Power voltage 24 V DC 12V 24V...

Page 67: ..._4 OUTPUT_1 3 For example Dipswitches 2 and 3 set to ON number 6 Physical address for first output will be 6 4 3 21 Physical address for 2nd output will be 22 Physical address for 3rd output will be 2...

Page 68: ...Speaker GL2 Speaker GND Microphone GND 441 Microphone G8 8 level of buttons G7 7 level of buttons G6 6 level of buttons G5 5 level of buttons G4 4 level of buttons G3 3 level of buttons G2 2 level of...

Page 69: ...GS GROUP OF DIGITISERS If entrance panel has more than 24 buttons it is necessary to create a group of digitisers One Group consists of max 4 digitisers and can managed up to 96 buttons Group can be s...

Page 70: ...tion To program door phone connect to the other power unit exit the programming mode first and start from the beginning setting new number of power unit 7 Press button PROG for 3 seconds to exit Dipsw...

Page 71: ...L GND 5 GND GND RS232 is used for connection switchboard with PC for example for download user s repertory or update the software PIN Mark Description 1 GND GND 2 RX in RS232 input 3 TX out RS232 outp...

Page 72: ...UPPLY ID Enter number of power supply connected to relevant panel and press to confirm If panel is connected to the main channel main entrance just press The following will appear ENTRANCE PANEL ID En...

Page 73: ...d press to confirm NO ACTION Relay will be not activated by any events 3 TIME SETTINGS In the stand by mode switchboard station shows actually time and data This function is used also for automaticall...

Page 74: ...estore default settings of the switchboard station The following will appear DEFAULT SETTINGS RESTORE Press to exit Press to confirm The following will appear WAIT Default settings will be restoring i...

Page 75: ...y on display appears number of event with time and data LED next to button switches on 19 10 2007 20 53 EVENT 1 Conversation can be disconnected by pressing button on the call module keyboard or by ha...

Page 76: ...tch on night mode is indicated by lighting up LED next to button Automatic change from day to night mode is also indicated by lighting up LED next to button In the night service all calls from entranc...

Page 77: ...1001 Press to confirm an old one To change logical user code press to delete old one enter new logical user code and confirm by pressing The following will appear NAME KOWALSKI You can confirm old na...

Page 78: ...tchboard and main channel propably line D disconnected LACK OF DOOR PHONE Attempt to call disconnected door phone NO ANSWER User does not pick up the call ADJUSTMENT The switchboard station is pre adj...

Page 79: ...DIAGRAMS ONE MAIN AUDIO ENTRANCE PANEL http www miwiurmet com pl e mail miwi miwiurmet com pl 79...

Page 80: ...DIAGRAMS ONE MAIN AUDIO ENTRANCE PANEL EXTENDED VERSION http www miwiurmet com pl e mail miwi miwiurmet com pl 80...

Page 81: ...DIAGRAMS THREE MAIN AUDIO ENTRANCE PANELS http www miwiurmet com pl e mail miwi miwiurmet com pl 81...

Page 82: ...DIAGRAMS ONE MAIN AND THREE ADDITIONAL AUDIO ENTRANCE PANELS http www miwiurmet com pl e mail miwi miwiurmet com pl 82...

Page 83: ...DIAGRAMS MASTER SLAVE STRUCTURE WITH SWITCHBOARD STATION http www miwiurmet com pl e mail miwi miwiurmet com pl 83...

Page 84: ...DIAGRAMS ONE VIDEO ENTRANCE PANEL COAX VERSION http www miwiurmet com pl e mail miwi miwiurmet com pl 84...

Page 85: ...DIAGRAMS ONE VIDEO ENTRANCE PANEL COAX VERSION WITH DISTRIBUTORS http www miwiurmet com pl e mail miwi miwiurmet com pl 85...

Page 86: ...DIAGRAMS ONE VIDEO ENTRANCE PANEL UTP VERSION http www miwiurmet com pl e mail miwi miwiurmet com pl 86...

Page 87: ...DIAGRAMS ONE VIDEO ENTRANCE PANEL UTP VERSION WITH DISTRIBUTORS REF 1752 54 http www miwiurmet com pl e mail miwi miwiurmet com pl 87...

Page 88: ...DIAGRAMS THREE VIDEO ENTRANCE PANELS UTP VERSION WITH DISTRIBUTORS http www miwiurmet com pl e mail miwi miwiurmet com pl 88...

Page 89: ...DIAGRAMS DECODER REF 1052 34 UTP VERSION WITH DISTRIBUTORS http www miwiurmet com pl e mail miwi miwiurmet com pl 89...

Page 90: ...DIAGRAMS DECODER REF 1052 34 UTP VERSION WITH DISTRIBUTORS http www miwiurmet com pl e mail miwi miwiurmet com pl 90...

Page 91: ...DIAGRAMS DECODER REF 1052 34 UTP VERSION WITH DISTRIBUTORS http www miwiurmet com pl e mail miwi miwiurmet com pl 91...

Page 92: ...DIAGRAMS ONE ANALOGUE ENTRANCE PANEL SYSTEM WITH DIGITALIZER http www miwiurmet com pl e mail miwi miwiurmet com pl 92...

Page 93: ...DIAGRAMS THREE ANALOGUE ENTRANCE PANELS SYSTEM WITH DIGITALIZERS http www miwiurmet com pl e mail miwi miwiurmet com pl 93...

Page 94: ...DIP SWITCH AND JUMPERS SETTINGS TABLE OF VIDEO BRACKET SETTINGS http www miwiurmet com pl e mail miwi miwiurmet com pl 94...

Page 95: ...DIP SWITCH AND JUMPERS SETTINGS TABLE OF DOOR PHONE SETTINGS http www miwiurmet com pl e mail miwi miwiurmet com pl 95...

Page 96: ...DIP SWITCH AND JUMPERS SETTINGS DIGITALIZER SETTINGS http www miwiurmet com pl e mail miwi miwiurmet com pl 96...

Page 97: ...NOTES NOTES http www miwiurmet com pl e mail miwi miwiurmet com pl 97...

Page 98: ...98 MIWI URMET Co Ltd ul Pojezierska 90A 90 341 Lodz Poland tel 004842 616 21 00 fax 004842 616 21 12 http www miwiurmet com pl e mail miwi miwiurmet com pl...

Reviews: