ERRORS REPORT
ADJUSTMENT
http://www.miwiurmet.com.pl e-mail:[email protected]
24
ERRORS REPORT
Call modules detect and identify lots of errors in Matibus SE
system. Communication about detected errors will be shown on the
LED display with correct code credited to specific error. Based on
this communication we are able to define what kind of problem
happened.
In the table below we present list of errors code with explanation.
E
r
0
1
Short-circuit in riser 1
E
r
0
2
Short-circuit in riser 2
E
r
0
3
Entering call code too slow
E
r
0
4
Logical user code has not been programmed
E
r
0
5
Incorrect open code
E
r
0
6
Line busy
E
r
0
7
Incorrect installer code
E
r
0
8
User code without assigned Dallas key
E
r
0
9
Incorrect physical code
E
r
1
0
Inactivity time too long (in programming
mode)
E
r
1
1
Several door phones with the same address
E
r
1
2
Dallas key already assigned
E
r
1
3
EEPROM full
-
-
-
-
Lack of communication between keyboard
and supplier, for example line D
disconnected
ADJUSTMENT CALL MODULES 1052/10../10D,
1052/11…/11D, 1052/15…/15D, 1052/16…/16D
Panel’s PCB is pre-adjusted during the manufacturing process.
Potentiometers "P1", "P2", "P3" allow adjustment of the panel,
however, should perform this step only if it is really necessary.
Function
P1
Adjusting the local effect
P2
Adjusting the call module speaker volume
P3
Adjusting the sensitivity of the microphone
J1 connector allows adjustment the electric lock current.
Jumpers
location
Value of current
Current of electrical lock around 150mA (work
with the reverse electrical lock)
Current of electrical lock around 300mA
Current of electrical lock around 600mA
1
0
*
#
9
8
7
6
5
4
2
3
P3
P2
P1