2 RELAY OUTPUTS
Switchboard station has 8 built-in NO-C-NO relays. Activation any
of the relays is confirmed by turning on relevant LED.
Each relay can be activated by different events, for example calling
switchboard from door phone number 1011 will activate relay
number 1.
Using
select relay number, press
to edit.
RELAY: 1 F:1
NO ACTION
Up to 16 different events (calling from door phone or entrance
panel) can be associated to one relay. Number next to letter F
indicates number of function.
Use
to scroll the list of function. Press
to modify.
In the edition mode use
to choose one of the 3 options
(calling to switchboard from door phone, calling to switchboard from
entrance panel, no action). Press
to confirm and set
parameters. Press
if you want return to the previous level.
You can choose:
CALL F. D. PHONE (CALL FROM DOOR PHONE)
Relay will be activated by calling switchboard from door phone.
The following will appear:
CALL F. D. PHONE
FROM 0 TO 0
Enter range of address (first address, press
, last address and
press
).
CALL F. E. PANEL (CALL FROM ENTRANCE PANEL)
Relay will be activated by calling switchboard from entrance panel.
The following will appear:
CALL F. E. PANEL
SUP_ ENT_
Enter number of power supply connected to additional entrance
panel, press
. In case of main entrance panel, press
without
giving number of power supply.
Enter ID panel, and press
to confirm.
NO ACTION
Relay will be not activated by any events.
3 TIME SETTINGS
In the stand-by mode switchboard station shows actually time and
data. This function is used also for automatically switching day/night
service.
Enter data/time and press
to confirm. Press
to delete
character if you make mistake.
4 PROGRAMMING THE ACCESS PASSWORD
Password could be 4-8 character long.
The following will appear:
ENTER NEW PASSWORD
To change password enter old password, press
after that enter
new password and press
to confirm.
To deactivation password function, enter old password and double
press
.
Press
to exit without saving.
5 SOUND OF KEYBOARD
Use
to turn on/off sound of switchboard station keyboard.
Press
to confirm.
6 DAY/NIGHT SERVICE
Night service: In this mode all calls from entrance panels are
called forward to switchboard station.
Day service: In this mode concierge service is disabled. Calls
made from panels are sent directly to the door phones.
There are 3 ways to day/night service changeover:
Mode
Description
Manual
Press
to set night service.
automatic
Switch on night service either by pressing
or by built-in clock.
Automatic
Switch on night service by built-in clock.
Use
to select the option, press
to confirm.
If you choose automatic or automatic mode, the following
will appear:
SWITCH ON
00:00
Enter night service switch on time, press
to confirm.
SWITCH OFF
00:00
Enter night service switch off time, press
to confirm.
7 LANGUAGE
The following languages can be set:
- Polish
- English.
8 SWITCHBOARD VERSION
This option let you know the software version (and date) installed in
the switchboard station., Press