PROGRAMMING MODE
http://www.miwiurmet.com.pl e-mail:[email protected]
43
7.03 PROGRAMMING NUMBER OF KEYBOARD FOR EI
TERMINAL
IN
THE
POWER
SUPPLY
FOR
THE
ADDITIONAL CHANNEL
P 7 0 3
In this step we are able to set the number of call module keyboard,
by this module we can turn on NC-C-NO relay exit, if we turn on
terminal EI in the power supply which is serving this call module.
We are able to set:
1 - 239 - number of selected keyboard,
0
- all keyboards,
255
- no keyboard.
To save new parameter please press
button.
Default settings
- 255
7.04 TOP RANGE OF CALL CODES OPERATED BY
SWITCHBOARD FOR RISER 1
P 7 0 4
In this step we are able to set:
•
Top range of physical user code served by switchboard,
•
Number and range of logical user codes generate
automatically in step 4.1.
•
Step 7.4 is no used if user codes are generate manual (step
5.1)
We can set:
1 - 255 - range of the house phones
To save new parameter please press
button.
Default settings
- 25
7.05 TOP RANGE OF CALL CODES OPERATED BY
SWITCHBOARD FOR RISER 1
P 7 0 5
In this step we are able to set:
•
Top range of physical user code served by switchboard,
•
Number and range of logical user codes generate
automatically in step 4.1.
•
Step 7.5 is no used if user codes are generate manual (step
5.1)
We can set:
1 - 255 - range of the house phones
To save new parameter please press
button.
Default settings
- 25
7.06 FREQUENCY OF ELECTRIC DOOR LOCK MODE
P 7 0 6
In this step we are programming frequency of electric door lock
mode, which is connected to call module by terminals +CL –CL.
These terminals are able to service electric door lock for DC and
AC voltage. Parameter which we will choose in this part of the
programming mode, set the frequency of the voltage which show on
the terminals +CL –CL.
Below table shows dependence between chosen parameter and
frequency of electric lock:
Parameter
Frequency
0
DC
1
500Hz
2
250Hz
3
166Hz
4
125Hz
5
100Hz
6
83Hz
7
71Hz
8
62Hz
9
55Hz
10
50Hz
11
45Hz
12
41Hz
13
38Hz
14
35Hz
15
33Hz
16
31Hz
17
29Hz
18
27Hz
19
26Hz
20
25Hz
To save new parameter please press
button.
Default settings
- 15
7.07 ELECTRIC DOOR LOCK TIME OF CURRENT DC
P 7 0 7
In first phase electric door lock works with DC current after strictly
definite time appears AC current.
After pressing the
button on the LED display will be shown actual
time of DC current in ms. You can confirm this value by pressing
the
button or change by entering new value in range from 0 –
250 ms
To save old or new parameter please press
button.
Default settings
-250
7.08 OTHER HOUSE PHONES BUTTONS
P 7 0 8
House phones ref. 1131/521 and ref. 1132/521 have an additional
button (or extra buttons) to call switchboard or control OC in the
power supply. This is realized through the inclusion of an adequate
resistance in parallel with the line. The power supply recognizes two
thresholds resistance: 180
Ω
and 68
Ω
We can choose:
0
- 180
Ω
OC is attached and 68
Ω
calls switchboard,
1
- 180
Ω
calls switchboard and 68
Ω
OC is attached.
To save new parameter please press
button.
Default settings
- 0