PROGRAMMING MODE
http://www.miwiurmet.com.pl e-mail:[email protected]
36
0.01 – 0.09 PARAMETERS
These parameters can be changed only if all else fails, when
system works improperly (for example problems with making a call)
and all other possible source of problems are eliminated.
1. MAIN SETUP
1.01 EDIT AND CHANGING ENTER PASSWORD
P 1 0 1
To change the password press
. Than the LED display will turn
off and we are able to enter any 8 digits password. Confirm of every
enter digit will be shown on display like a vertical line. At the LED
display will be shown this communication:
II II II II
To save changed password press
.
Default password -
21082004
1.02 EDIT THE ID OF THE CALL MODULE
P 1 0 2
To change the call module ID press
. Than LED display will show
actual ID of call module. We are able to enter new ID in range from
1 to 239 and confirm by pressing
.
Setting of this parameter is reasonable only when there is many
entrances.
Default settings
- draw in range from 1 to 239
1.03 AUTOMATIC USER CODE CONFIRMATION
P 1 0 3
There are two ways to choose the logical user code:
0
Enter the code without pressing
button after
1
Enter the code and press
button to confirm.
To save changes press
.
Default settings
- 0
1.04 PERSONAL OPENING CODE USING CONFIRMATION
P 1 0 4
In this step we are setting parameter responsible for short signal
played in the house phone when individual opening code
associated with that house phone was used. We can choose:
0
Turn off confirmation of opening the door and exit
NC-C-NO
1
Turn on confirmation of opening the door
2
Turn on confirmation of opening the exit NC-C-NO
3
Turn on confirmation of opening the door and exit NC-NO
To save entered parameters press
.
Default settings
- 3
1.05 SOUND LEVEL OF THE KEYBOARD
P 1 0 5
Sound intensity of the audible signals produced by the call module.
0
Turn off the signals
1
Turn on- low level of signals
2
Turn on- high level of signals
To save entered changes press
.
Default settings
- 1
1.06 TYPE OF USER CODES
P 1 0 6
Parameter sets in this step determine type of user code using in
system.
0
Logical codes
1
Physical codes
To save entered changes press
.
Default settings
- 0
Logic code-
this is max. 4 digits code from full range from
1 to 9999, which is programmable to any
physical code. Logical code can be programmed
just to one physical code
Physical code format of this code is CFFF, where C is the
number of riser (1or 2) to which house phone is
physically connected, FFF is address of the
house phone which is the same binary value
what jumpers set in the house phone.
Example 1
If the house phone is connect to the riser 1 and jumpers are set as
an address 4, than to call we have to enter code 14, what will be
shown on LED display:
1 4
Example 2
If the house phone is connect to the riser 2 and jumpers are set as
an address 15 than to call we have to enter code 215, what will be
shown on LED display:
2 1 5