OPERATION INSTRUCTION
PROGRAMMING MODE
http://www.miwiurmet.com.pl e-mail:miwi@miwiurmet.com.pl
34
Individual opening code can be turned off in a programming mode.
If the door is opened by the individual opening code in the house
phone will be played short, confirmation signal and this function
also can be turned off in the programming module.
TURN ON NC-C-NO RELAY USING
GENERAL OPENING CODES
Using Matibus SE call module we are able to open any device (for
example automatic gate) using the NC-C-NO relay. To turn on
terminals NC-C-NO with one of the general codes enter 1 from 64
general 4 digits opening codes:
•
Double press
button,
•
Enter general opening code,
•
Confirm by pressing
button.
This function can be turned off in a programming mode.
Time to turn on NC-C-NO is programmable in range form 1s to 30s.
TURN ON NC-C-NO RELAY USING
INDIVIDUAL OPENING CODES
Using Matibus SE call module we are able to open any device (for
example automatic gate) using relay with terminals NC-C-NO. To
turn on terminals NC-C-NO with one of the individual codes:
•
Double press
button,
•
Enter individual opening code – from 5 to 8 digits,
•
Confirm by pressing button
button
This function can be turned off in a programming mode.
Time to turn on NC-C-NO is programmable in range form 1s to 30s.
If any of the devices will be opened by the individual opening code
in the house phone will be played short, confirmation signal.
EXI TERMINAL
The Matibus SE call module is equipped with terminal EXI. Default
settings are that terminal EXI is connected with GND terminal.
Sensor assembled between this connection allows system to
control EO output in power supply (on terminal EO appears +20
VDC if EXI-GND circuit is disconnect). This function could be use to
indicate opened door.
FUNCTION OF TERMINAL PH
The Matibus SE call module is equipped with terminal PH, which is
performing for local opening door. Connection PH and GND lead to
turn on electric lock for programmed time. To implement this
function, during the installation between terminals PH and GND
have to be added a button which perform this function.
FUNCTION OF TERMINAL R
The Matibus SE call module is equipped with terminal R, which is
output in the form of open collector. From the start of conversation
till the end this output will be activated and connected to the ground.
Terminal R is dedicated to service video version, but the way of use
is up to our needs.
PROGRAMING MODE
Matibus SE call module is coming with already elementary
programmed menu to make this system easier and more friendly for
the installer.
•
Personal user codes are range from 1 to 25 in each riser
•
All the individual opening codes are unique for each power
supply and random.
•
Electric lock is open for 3s.
•
Time of calling- 5 s,
•
Pick up time 20 s,
•
Maximum time of conversation 120 s.
Thanks to already programmed menu system MATIBUS needs just
the properly connection according to the diagram and set the
jumpers in house phones.
MASTER power supply is programmed by call module connected to
main or additional channel.
SLAVE power supply is programmed by call module connected to
that one power supply (additional channel).
ENTERING TO THE PROGRAMMING MODE
In order to enter to the programming mode:
•
Double press
0
button,
•
Entering 8 digits Access password,
•
Confirm password by pressing the
button.
Default enter password is : 21082004
After enter the correct password on the LED will display this
information:
P 1 0 1
PROGRAMMING MENU
In the programming menu are two levels of programming. It means
that after letter “P” there are place for 3 digits number, where every
digit is one level of programming mode. Every level is defined in
range from 1 to 9. The level of programming mode is display on the
LED just like it has been shown below.
P X X X
Where XXX is 3 digits number informing installer about actual part
of programming mode.