ÜKY/Duopel Boilers User Manual

 

RULES FOR HEATING INSTALLATION 

 

Circulation pump:  
A pump with sufficient capacity and a pump system is recommended. The capacity 
of the required pump is determined taking into account the resistances formed in 
the  installation.  The  wiring  diagrams  given  in  the  manual  should  be  taken  as 
reference to determine the correct position of the pump in the system. The pump 
stage should be adjusted considering the resistance in the installation. 

 

In addition to the schematic installation connection shown in high capacity boiler assemblies, a backup pump 
system should be made. By-pass line should be connected directly as backup pump line, primary pump. Boiler 
inlet and outlet lines should be connected with collectors. In order to prevent the system from making air, in 
open expansion installations, the head of the pump should be less than the height of the expansion. 
In the assembly of the circulation pump, the electrical connections not coming down will eliminate the problem 
of possible water entering into the pump. Vertical mounting of the shaft should also be avoided to prevent the 
pump shaft from pressing on the body or outer cover during operation. 

 

Expansion tank: 
In hot water heating systems, when the water is heated from 10ºC to 90ºC, its volume increases by 3.55% of its 
initial volume. "Expansion tanks" are used to get this expansion depending on the temperature in the water. 
Expansion tanks also fulfill the safety of the system, that is, the pressure does not rise, and the necessary water 
supply duties to the system. Since DUOPEL series boilers can also be loaded manually, an open expansion tank 
is mandatory. 

 

It is placed at the top of the system that is, on the roof, works with a level difference 
and open to the atmosphere. The expansion tank is placed at a slightly higher point 
than  the  highest  point  of  the  dispensing  system  to  collect  the  expanding  water 
volume.  The  water  expanding  in  the  boiler  is  stored  in  the  expansion  tank  through 
the flow safety pipe. When the water in the installation cools, the reduced water of 
the installation is  completed  by the expansion tank  through the return safety pipe. 
Since the expansion tank opens the system to the atmosphere, it ensures the safety 
of the system by preventing the pressure in the heating installation from rising above 
the atmospheric pressure. Air pipes in the system are evacuated by opening the air 

pipes to the atmosphere from the expansion tank. It is recommended to use separate expansion tanks for each 
boiler in the installation, according to their capacities. So it is not right to connect two boilers to one expansion 
tank. There are flow and return safety pipes for each boiler and expansion tank. Valves, check  valves etc. on 
these safety pipes. No fittings such as material should be installed. The safety pipes should reach the nearest 
point of the boiler inlet and outlet from the shortest vertical path. Horizontal movement is permitted only at 
the level of the expansion tank and the minimum length. 

 

ÜNMAK DUOPEL series solid fuel boilers must be connected to an installation with an open expansion tank in 
accordance with the installation scheme shown below. The circulation pump can be connected on the flow or 
return line. In case the pump is at the return of the boiler; open expansion tank should be higher than the head 
of the pump. 

 

Warning about water level: 
After  the  first  water  is  pumped  into  the  system,  the  minimum  water  level  should  be  marked  on  the 
hydrometer. The  water level  should be checked  daily, and water should be added to the installation when it 
falls  below  the  minimum  value.  Open  expansion  tank  volumes,  which  should  be  according  to  Ünmak  boiler 
capacities,  are  given  in  the  table  above.  Open  expansion  tanks  are  selected  by  assuming  Ünmak  brand  open 
expansion volumes and panel radiators in the system.  

BOILER 
POWER 
(kW) 

OPEN 
EXPANSION 
VOLUME (Lt) 

25 

50 

40 

90 

60 

90 

80 

110 

100 

210 

Summary of Contents for UKY/DUOPEL 100

Page 1: ...KY Duopel Boilers User Manual NL SOY Yap Malzemeleri Sanayi ve Ticaret Ltd ti Pancar Organize Sanayi B lgesi 2 Etap No 2 Torbal ZM R TURKEY Tel 90 444 35 32 Fax 90 232 469 2412 www unmak com...

Page 2: ...OTICES 6 ELECTRIC INSTALLATION INSTRUCTIONS 8 INFORMATION ABOUT COMBUSTION 10 BOILER FEAUTURES 12 RULES FOR HEATING INSTALLATION 14 CONTROL PANEL AND USER INTERFACE 17 START UP 19 FUEL FEEDING STANDBY...

Page 3: ...ting heating installations not directly for domestic water heating However it can produce hot tap water with the help of a boiler or heat exchanger The energy required for potable water will be taken...

Page 4: ...a sufficient capacity In order not to damage the boiler outer sheets and the boiler during transportation While carrying the rope on the forklifts on the chassis and carrying the boiler with the help...

Page 5: ...the boiler room this is the most suitable solution The door of the boiler room should not be opened directly to the escape staircase or general use staircases and must be opened to a common hallway or...

Page 6: ...d Laying the mounting place with tiles and tile stones makes cleaning easier It is inconvenient to keep flammable burning and easily flammable substances in the boiler room Mounting location dimension...

Page 7: ...himney walls should not be less than the thickness of a brick Hollow brick and briquette should never be used in chimney construction It should be plastered inside and outside and cylindrical pipe ins...

Page 8: ...ure that the proportion between the installation water flow rate and the boiler power and the 20 C difference between the boiler inlet and outlet water temperatures are not exceeded To minimize the co...

Page 9: ...ate hot dip or c Solid copper rod should be made with electrodes Copper rod electrodes must be at least 1 5 m in diameter of 16 mm or at least 1 25 m in diameter of 20 mm and the earthing resistance o...

Page 10: ...P a g e 9 KY Duopel Boilers User Manual Elektrik Ba lant emas...

Page 11: ...1 4 of the chimney height The height of the chimney should be determined well and the chimney rising from the building should rise at least 80 cm from the ridge Unless compulsory the chimney sections...

Page 12: ...1 meter above flat roofs and at least 0 4 meters above tiled roofs Excess air at high flue temperature high flue temperature also causes loss of combustion efficiency Excess air causes high flue temp...

Page 13: ...llation from this pipe 5 Return line It is the pipe through which the water returned from the radiators or heating installation returns to the boiler It can also be called return pipe or return line 6...

Page 14: ...510 585 Draft Pa 25 28 31 33 33 35 35 40 Temperature Control Range o C 40 90 Return Temperature Recommended o C 40 Maximum Operation Pressure bar 3 Test Pressure bar 5 Dimensions Boiler Width A mm 10...

Page 15: ...he dispensing system to collect the expanding water volume The water expanding in the boiler is stored in the expansion tank through the flow safety pipe When the water in the installation cools the r...

Page 16: ...P a g e 15 KY Duopel Boilers User Manual Open expansion tank installation scheme...

Page 17: ...orrectly to minimize the addition of fresh water None of the materials used in the installation should be gas permeable Maximum 50 micron filter with synthetic or metal mesh should be placed on the fr...

Page 18: ...nto the device It is used to increase or decrease the values of Fan Setting Temperature Setting Fuel Supply and Fuel Standby ENTER It is used for storing the set values and for entering submenus from...

Page 19: ...is activated and deactivated with this button Manuel Fuel Feeding It is used to manually manually add fuel to the boiler As long as the button is pressed fueling continues Wood Mode It is used when i...

Page 20: ...ic feeding Fill the hopper with wood pellet and close the cap tightly Open the control panel by pressing the ON OFF button of the device for 1 second When turned on values will appear next to Feed Set...

Page 21: ...remain at Level 1 during the ignition Find the Fuel Feed and Fuel Standby settings in the Fuel Standby Feed Settings section of your manual which should be based on the boiler power and fuel type Pre...

Page 22: ...en You can hold down the buttons until the temperature level you want to adjust When it reaches the desired degree you can save it by pressing the ENTER button Press the Fan Setting button of the pane...

Page 23: ...ording to the chimney draft and the thermal comfort demand of the space In power cuts close the flue flap if any If the pump bypass line is available activate the line When the electricity comes do no...

Page 24: ...ash collected between the blades of the fan it is necessary to clean it by blowing or holding a dryer without disturbing the blades of the fan Cleaning the boiler It should be done when the boiler is...

Page 25: ...of plastic derivative into the boiler or fuel reservoir hopper Check that there are no holes or cracks in the chimney If you still can t consult your leg Have your chimney sealed Excessive fuel consum...

Page 26: ...e If using automatic add fuel to the hopper manually load fuel if mechanical feeding is used Replace probe or call service Replace probe or call service If using automatic add fuel to the hopper if us...

Reviews: