ÜKY/Duopel Boilers User Manual

 

INFORMATION ABOUT COMBUSTION 

 

As a general rule, the air supplied to the fuel should be at a certain rate to 
ensure  correct  combustion.  So  the  fan  speed  should  be  adjusted  well. 
The air required for a certain amount of fuel should not be too much. If 
the  amount  of  air  varying  depending  on  the  type  of  fuel  is  less  than 
necessary, carbon monoxide  is  formed,  the  energy produced  decreases, 
processing  begins,  the  combustion  efficiency  decreases,  when  the 
amount  of  air  is  more  than  necessary,  while  the  carbon  monoxide 
decreases,  the  air that  does  not  enter  the  combustion  is  removed  from 
the  chimney  by  being  heated  in  the  furnace,  combustion  deteriorates, 
combustion efficiency. It decreases. 
 
If  the  flue  gas  temperature  is  above  the  accepted  values,  much  energy 
will  be  thrown  from  the  flue  to  the  atmosphere.  The  material, 

construction and connection of the chimneys are important in terms of high combustion efficiency, 
low heating costs and environmental protection. 
 
For the combustion to be good, the chimney must also be good. High temperature resistant firebrick 
and stainless steel chimneys are recommended as a material. Horizontal smoke channels should be 
connected to the chimney with a rising slope of at least 5% and its length should never exceed 1/4 of 
the  chimney  height.  The  height  of  the  chimney  should  be  determined  well  and  the  chimney  rising 
from the building should rise at least 80 cm from the ridge. Unless compulsory, the chimney sections 
should be circular.  
 
Perforated bricks should never be used on chimney walls. Ideally, it is knitted with firebrick. ÜNMAK 
boilers  should  be  connected  to  an  independent  chimney  that  can  provide  the  minimum  desired 
minimum draft. Minimum draft is generally min. It should be measured with a manometer in 20 Pa. 
The  part of  the  waste  gas line  between  the  boiler  and  the  chimney  should  be  insulated  with  glass 
wool. The flue gas pipe and chimney should be made of steel sheet or material resistant to around 
400 °C. All connections on the flue gas pipe must be sealed for better combustion and efficiency. The 
waste gas pipe should be connected to the chimney in the shortest way, within the dimensions given 
in  the  diagram  below.  Horizontal  connections  and  equipment  such  as  elbows  that  reduce  draft 
should be avoided. 

 
A  vertical  singular  steel  pipe 
should not be used as a chimney, 
the  chimney  must  have  an  inner 
and  an  outer  surface.  The  outer 
surface  may  be  steel  or  brick 
braided.  For  the  inner  surface  of 
the  chimney,  corrosion-resistant 
stainless  steel  can  be  preferred. 
To prevent condensation, thermal 
insulation  should  be  made  in  the 
gap  between  the  inner  and  outer 
surface of the chimney. 
At  the  lowest  level  of  the 
chimney,  there  should  be  a 
cleaning cover made of all kinds of 

sealed steel. 

Summary of Contents for UKY/DUOPEL 100

Page 1: ...KY Duopel Boilers User Manual NL SOY Yap Malzemeleri Sanayi ve Ticaret Ltd ti Pancar Organize Sanayi B lgesi 2 Etap No 2 Torbal ZM R TURKEY Tel 90 444 35 32 Fax 90 232 469 2412 www unmak com...

Page 2: ...OTICES 6 ELECTRIC INSTALLATION INSTRUCTIONS 8 INFORMATION ABOUT COMBUSTION 10 BOILER FEAUTURES 12 RULES FOR HEATING INSTALLATION 14 CONTROL PANEL AND USER INTERFACE 17 START UP 19 FUEL FEEDING STANDBY...

Page 3: ...ting heating installations not directly for domestic water heating However it can produce hot tap water with the help of a boiler or heat exchanger The energy required for potable water will be taken...

Page 4: ...a sufficient capacity In order not to damage the boiler outer sheets and the boiler during transportation While carrying the rope on the forklifts on the chassis and carrying the boiler with the help...

Page 5: ...the boiler room this is the most suitable solution The door of the boiler room should not be opened directly to the escape staircase or general use staircases and must be opened to a common hallway or...

Page 6: ...d Laying the mounting place with tiles and tile stones makes cleaning easier It is inconvenient to keep flammable burning and easily flammable substances in the boiler room Mounting location dimension...

Page 7: ...himney walls should not be less than the thickness of a brick Hollow brick and briquette should never be used in chimney construction It should be plastered inside and outside and cylindrical pipe ins...

Page 8: ...ure that the proportion between the installation water flow rate and the boiler power and the 20 C difference between the boiler inlet and outlet water temperatures are not exceeded To minimize the co...

Page 9: ...ate hot dip or c Solid copper rod should be made with electrodes Copper rod electrodes must be at least 1 5 m in diameter of 16 mm or at least 1 25 m in diameter of 20 mm and the earthing resistance o...

Page 10: ...P a g e 9 KY Duopel Boilers User Manual Elektrik Ba lant emas...

Page 11: ...1 4 of the chimney height The height of the chimney should be determined well and the chimney rising from the building should rise at least 80 cm from the ridge Unless compulsory the chimney sections...

Page 12: ...1 meter above flat roofs and at least 0 4 meters above tiled roofs Excess air at high flue temperature high flue temperature also causes loss of combustion efficiency Excess air causes high flue temp...

Page 13: ...llation from this pipe 5 Return line It is the pipe through which the water returned from the radiators or heating installation returns to the boiler It can also be called return pipe or return line 6...

Page 14: ...510 585 Draft Pa 25 28 31 33 33 35 35 40 Temperature Control Range o C 40 90 Return Temperature Recommended o C 40 Maximum Operation Pressure bar 3 Test Pressure bar 5 Dimensions Boiler Width A mm 10...

Page 15: ...he dispensing system to collect the expanding water volume The water expanding in the boiler is stored in the expansion tank through the flow safety pipe When the water in the installation cools the r...

Page 16: ...P a g e 15 KY Duopel Boilers User Manual Open expansion tank installation scheme...

Page 17: ...orrectly to minimize the addition of fresh water None of the materials used in the installation should be gas permeable Maximum 50 micron filter with synthetic or metal mesh should be placed on the fr...

Page 18: ...nto the device It is used to increase or decrease the values of Fan Setting Temperature Setting Fuel Supply and Fuel Standby ENTER It is used for storing the set values and for entering submenus from...

Page 19: ...is activated and deactivated with this button Manuel Fuel Feeding It is used to manually manually add fuel to the boiler As long as the button is pressed fueling continues Wood Mode It is used when i...

Page 20: ...ic feeding Fill the hopper with wood pellet and close the cap tightly Open the control panel by pressing the ON OFF button of the device for 1 second When turned on values will appear next to Feed Set...

Page 21: ...remain at Level 1 during the ignition Find the Fuel Feed and Fuel Standby settings in the Fuel Standby Feed Settings section of your manual which should be based on the boiler power and fuel type Pre...

Page 22: ...en You can hold down the buttons until the temperature level you want to adjust When it reaches the desired degree you can save it by pressing the ENTER button Press the Fan Setting button of the pane...

Page 23: ...ording to the chimney draft and the thermal comfort demand of the space In power cuts close the flue flap if any If the pump bypass line is available activate the line When the electricity comes do no...

Page 24: ...ash collected between the blades of the fan it is necessary to clean it by blowing or holding a dryer without disturbing the blades of the fan Cleaning the boiler It should be done when the boiler is...

Page 25: ...of plastic derivative into the boiler or fuel reservoir hopper Check that there are no holes or cracks in the chimney If you still can t consult your leg Have your chimney sealed Excessive fuel consum...

Page 26: ...e If using automatic add fuel to the hopper manually load fuel if mechanical feeding is used Replace probe or call service Replace probe or call service If using automatic add fuel to the hopper if us...

Reviews: