138
XI.
IRC MESSAGES
Following messages are displayed on the master ECR or the slave ECRs in IRC communication:
Displayed on Slave ECR
--- IRC COMM ---
Displayed on the top when a slave ECR is in IRC communication.
Displayed on Master ECR
-- IRC BUSY --
Displayed on the top when a slave ECR is in IRC communication, or when the communication line
is being used by other ECR for slip printer transmission, etc.
ECR-xxx ->
Displayed on the bottom when master ECR is in IRC communication of report collection or
program download.
ECR#-xxx <-
Displayed in the floating track/clerk operation when master ECR requires a slave #
xxx
to send a
track or clerk's data.
ECR-xxx OFF
Displayed while the master is taking IRC Z report when a slave #
xxx
is in error (can not
communicate), or when the power is 'off,' or the cable being disconnected.
ECR#-xxx BUSY
Displayed when a slave #
xxx
is processing a transaction, or
when a transaction is closed but some compulsory conditions still remain, or
when the same track or clerk is used by the floating track/clerk operation.
ECR#-xxx ERROR
Displayed in the floating track/clerk operation when a slave #
xxx
is in error (can not
communicate), or when the power is 'off', or the cable being disconnected.
Floating Item Track
REQ.Z62-xxx
TTTTTTT
Displayed when a communication error occurs after receiving item track data from a slave #
xxx
. It
requires to delete the track #
TTTTTTT
on the slave #
xxx
by Z-62 individual item track report.
Because two tracks having same number will exist on the master and slave.
REQ.X62-xxx
TTTTTTT
Displayed when master ECR can not check that the item track data is surely deleted from a slave
#
xxx
. It requires to check the track #
TTTTTTT
on the slave #
xxx
by X-62 individual item track
report.
Floating Amount Track
REQ.Z66-xxx
TTTTTTT
Displayed when a communication error occurs after receiving the amount track data from a slave
#
xxx
. It requires to delete the track #
TTTTTTT
on the slave #
xxx
by Z-66 individual amount
track report. Because two tracks having same number will exist on the master and slave.
REQ.X66-xxx
TTTTTTT
Displayed when master ECR can not check that the amount track data is surely deleted from a slave
#
xxx
. It requires to check the track #
TTTTTTT
on the slave #
xxx
by X-66 individual amount
track report.
Floating Clerk
REQ.Z70-xxx
CC
Displayed when a communication error occurs after receiving the clerk's data from a slave #
xxx
.
It requires to delete the data from the slave #
xxx
by Z-70 individual clerk balance report. Because
two clerks' data will exist on the master and slave.
CC
shows a sequential clerk number.
REQ.X70-xxx
CC
Displayed when master ECR can not check that the clerk's data is surely deleted from a slave #
xxx
.
It requires to check the clerks' data on the slave #
xxx
by X-70 individual track report.
CC
shows a sequential clerk number.
xxx: slave ECR's machine number