135
WM-#31
CHECK-OUT BILL ISSUE IS COMPULSORY
Press
CHECK-OUT BILL
key. (can be canceled by using
BILL CANCEL
key)
WM-#32
SLIP PAPER HAS NOT BEEN INSERTED
WM-#33
CURRENT ITEM TRACK / CLERK INTERRUPT MEMORY IS FULL
Close the item track or the clerk's transaction temporarily by
NB
(New Balance) key or close it by a
TOTAL
(media) key.
WM-#34
ENTIRE ITEM TRACK / CLERK INTERRUPT MEMORY IS FULL
Close the item track by
NB
(New Balance) key or the clerk's transaction temporarily by
STORAGE
or
NB
key,
then:
- close another item track, or
- another clerk's transaction by a media key to secure additional item track / clerk interrupt memory, or
- do the previous balance key operation.
This message is also displayed when all item tracks are used under the limited automatic item track number.
CHECKING THE NUMBER OF BLOCKS OF ITEM TRACK / CLERK INTERRUPT MEMORY
This function is used for checking the number of remaining blocks.
-
Set the control key to X position.
-
Press
ITEM TRACK #
key.
-
The number of remaining blocks is displayed.
*** TRACK SORT ***
356
number of remaining blocks (total 384 blocks)
After the item track or the clerk's transaction has been closed by a media key, the occupied blocks will become free.
To secure the memory of currently occupied transactions, a new transaction can not be opened, even if a few blocks
remain.
The maximum number of item tracks or clerk interrupt memories, that can be handled, depends on the number of
items registered per item track or clerk interrupt memory.
# of blocks
- 384 blocks are available.
- One transaction always occupies one block.
- Up to 24 blocks (max. 359 items) are used for one transaction.
- 1st block can memorize 7 items, and 2nd ~ 24th blocks 16 items per block.
# of item tracks/clerk interrupt memories
(max. 64 clerk interrupt memories)
Up to 384 (max.) item tracks/clerk interrupt memories can be used if 7 items each is registered.
Up to 150 item tracks/clerk interrupt memories can be used if 23 items each is registered.
Up to 100 item tracks or clerk interrupt memories can be used if 39 items each is registered.
Up to 50 item tracks or clerk interrupt memories can be used if 103 items each is registered.
Up to 30 item tracks or clerk interrupt memories can be used if 183 items each is registered.
Up to 16 item tracks or clerk interrupt memories can be used if 359 items (max.) each is registered.
For example, in case of 50 tracks: 384 blocks / 50 tracks = 7 (7.68) blocks / track, 7 items + 6 blocks * 16 items = 103 items
WM-#35
NEW BALANCE CLOSING OF ITEM TRACK IS COMPULSORY
(can be released temporarily by using
OFF COMPULSORY
key)
WM-#36
NEW BALANCE CLOSING OF ITEM TRACK IS PROHIBITED
WM-#37
ITEM TRACK # INPUT IS COMPULSORY
WM-#38
TABLE # INPUT FOR ITEM TRACK IS COMPULSORY
WM-#39
COOKING MESSAGE INPUT IS COMPULSORY
(WM-#37~39: can be released temporarily by using
OFF COMPULSORY
key)
WM-#40
ITEM / AMOUNT TRACK TRANSFER IS PROHIBITED
WM-#41
ITEM TRACK # NOT FOUND
WM-#42
SLIP PRINT IS COMPULSORY
(can be released temporarily by using
OFF COMPULSORY
key)
WM-#43
CLERK ID ERROR
The clerk was not assigned to the track in registration. Enter correct clerk code or use the correct clerk key.