background image

•  IMPORTANT: Read this entire manual before installing 

and operating this product. Failure to do so may result 

in property damage, bodily injury, or even death. 

Proper installation of this stove is crucial for safe and 

efficient operation.

• 

Install  vent  at  clearances  specified  by  the  vent 

manufacturer.

• 

If a chimney or creosote fire occurs, press the “OFF” 

button immediately. Do not unplug the unit.

•  Do not connect the pellet vent to a vent serving any 

other appliance or stove.

• 

Do  not  install  a  flue  damper  in  the  exhaust  venting 

system of this unit.

•  Use of outside air is not required for this unit.

• 

Contact  your  local  building  officials  to  obtain  a 

permit and information on any additional installation 

restrictions or inspection requirements in your area.

•  Do not throw this manual away. This manual has 

important operating and maintenance instructions 

that you will need at a later time. Always follow the 

instructions in this manual.

•  This appliance is designed for the use of pelletized fuel 

that meet or exceed the standard set by the Pellet Fuel 

Institute(PFI), The use of other fuels will void warranty.

•  Never use gasoline, gasoline-type lantern fuel, 

kerosene, charcoal lighter fluid, or similar liquids to start 

or ’freshen up’ a fire in this stove. Keep all such liquids 

well away from the stove while it is in use.

•  A working smoke detector must be installed in the 

same room as this product.

• 

It must be installed at least 15 feet (4,57 m) from the 

appliance in order to prevent undue triggering of the 

detector when reloading.

•  Do not unplug the stove if you suspect a malfunction. 

Turn  the  ON/OFF  SWITCH  to  ”OFF’  and  contact  your 

dealer.

•  Your stove requires periodic maintenance and 

cleaning  (see  ”MAINTENANCE  ”).  Failure  to  maintain 

your stove may lead to improper and/or unsafe 

operation.

•  Disconnect the power cord before performing any 

maintenance! NOTE: Turning the ON/OFF Switch to 

”OFF” does not disconnect all power to the electrical 

components of the stove.

•  Never try to repair or replace any part of the stove 

unless instructions for doing so are given in this manual. 

All other work should be done by a trained technician.

•  Do not operate your stove with the viewing door 

open. The auger will not feed pellets under these 

circumstances and a safety concern may arise from 

sparks or fumes entering the room.

•  The feed door must be closed and sealed during 

operation.

• 

Never block free airflow through the open vents of the 

unit.

•  DO NOT CONNECT TO OR USE IN CONJUNCTION WITH 

ANY AIR DISTRIBUTION DUCTWORK UNLESS SPECIFICALLY 

APPROVED FOR SUCH INSTALLATION.

•  Allow the stove to cool before performing any 

maintenance or cleaning. Ashes must be disposed 

in a metal container with a tight fitting lid. The closed 

container of ashes should be placed on a non-

combustible surface or on the ground, well away from 

all combustible materials, pending final disposal.

• 

The exhaust system should be checked monthly during 

the burning season for any build-up of soot or creosote.

•  Do not touch the hot surfaces of the stove. Educate all 

children on the dangers of a high-temperature stove. 

Young children should be supervised when they are in 

the same room as the stove.

•  The hopper and stove top will be hot during operation; 

therefore, you should always use some type of hand 

protection when refueling your stove.

•  A power surge protector is required. This unit must be 

plugged into a 110 - 120V, 60 Hz grounded electrical 

outlet. Do not use an adapter plug or sever the 

grounding plug. Do not route the electrical cord 

underneath, in front of, or over the heater. Do not 

route the cord in foot traffic areas or pinch the cord 

under furniture.

•  The heater will not operate during a power outage. 

If a power outage does occur, check the heater for 

smoke spillage and open a window if any smoke spills 

into the room.

•  Keep foreign objects out of the hopper.

•  The moving parts of this stove are propelled by high 

torque electric motors. Keep all body parts away from 

the auger while the stove is plugged into an electrical 

outlet. These moving parts may begin to move at any 

time while the stove is plugged in.

• 

Do not place clothing or other flammable items on or 

near this stove.

•  When installed in a mobile home, the stove must be 

grounded directly to the steel chassis and bolted to 

the floor. WARNING—THIS UNIT MUST NOT BE INSTALLED 

IN THE BEDROOM (per HUD requirements). CAUTION—

The structural integrity of the mobile home floor, wall, 

and ceiling/roof must be maintained.

•  This appliance is not intended for commercial use.

• 

Establish a routine for the fuel, wood burner and firing 

technique. Check daily for creosote build-up until 

experience shows how often you need to clean to be 

safe. Be aware that the hotter the fire the less creosote 

is deposited, and weekly cleaning may be necessary 

in mild weather even though monthly cleaning may 

be enough in the coldest months. Contact your local 

municipal  or  provincial  fire  authority  for  information 

on  how  to  handle  a  chimney  fire.  Have  a  clearly 

understood plan to handle a chimney fire.

* This appliance is a freestanding heater. It is not intended to be attached to any type of ducting. It is not a furnace.

Safety Precautions

Summary of Contents for King

Page 1: ...tallation and use of this appliance Failure to follow these instructions could result in property damage bodily injury or even death Contact your local building or fire officials about obtaining permi...

Page 2: ...TH ANYAIRDISTRIBUTIONDUCTWORKUNLESSSPECIFICALLY APPROVED FOR SUCH INSTALLATION Allow the stove to cool before performing any maintenance or cleaning Ashes must be disposed in a metal container with a...

Page 3: ...under 8 by weight ash under 1 by weight and salt under 300 parts per million Pellets that are soft contain excessive amounts of loose sawdust have been or are wet will result in reduced performance St...

Page 4: ...n death Warning Use all specified components and make no substitutions unless approved by the manufacturer Failure to do so may result in property damage bodily injury or even death See specific insta...

Page 5: ...ft hand side of your pellet stove may need to be greater than the minimum required clearance for suitable access to the control panel FIGURE 3 SIDEWALL CLEARANCES PARALLEL INSTALLATION FIGURE 4 SIDEWA...

Page 6: ...too close to neighbors or in a valley which may cause unhealthy or nuisance conditions PELLET VENT TYPE A UL listed 3 inch or 4 inch type PL pellet vent exhaust system must be used for installation an...

Page 7: ...ction of pipe should be added with a horizontal cap which would complete the installation see FIGURE 7 A support bracket should be placed just below the termination cap or one every 4ft 1 22m to make...

Page 8: ...nection to the heater SPECIAL MOBILE HOME REQUIREMENTS WARNING Do not install in a sleeping room CAUTION The structural integrity of the mobile home floor wall and ceiling roof must be maintained A wo...

Page 9: ...unt of heat produced by the stove is proportional to the rate of the fuel that is burned and this rate is controlled by the HEAT RANGE setting In order to maintain combustion of the fuel at a desired...

Page 10: ...ng the Draft Fan setting try only 1 setting above or below the heat setting It is better to leave the stove in the automatic mode ROOM FAN The room fan will come on once the unit has reached operating...

Page 11: ...tove cycle between the preselected desired heat range setting 1 to 5 and the minimum heat range setting of 1 The T Stat will not turn the stove on and off When the desired room temperature has been re...

Page 12: ...If the hopper switch is open lid is open the HEAT RANGE LED will turn on If the lid is closed the HEAT RANGE LED will be off 6 Thermostat Input Test The display will show stat If the thermostat input...

Page 13: ...reset If a chimney or creosote fire occurs press the OFF button immediately Do not unplug the unit DAILY OPERATION The hopper and stove top will be hot during operation therefore you should always use...

Page 14: ...fire Inspect the system at the stove connection and at the chimney top Cooler surfaces tend to build creosote deposits quicker so it is important to check the chimney from the top as well as from the...

Page 15: ...amming or similar trauma Do not operate the stove with the glass removed cracked or broken FALL START UP Prior to starting the first fire of the heating season check the outside area around the exhaus...

Page 16: ...to the firebox is free of ash or clear of obstructions The auto start igniter gets red hot during start up If you can not visibly see the igniter glowing during start up then the igniter may need to...

Page 17: ...own state waiting for the OFF button or for a 15 minute period after the stove was turned off or for the stove to cool down or for the door to be closed Flashing dash in Heat Range Display This indica...

Page 18: ...5692 Handle Door 1 3 83506 3 8 x 1 1 4 Roll Pin 1 4 891053 Door Glass 1 5 88066 5 8 Rope Gasket 4 5 ft 6 88087 Glass Gasket 1 x 1 3 16 3 ft 7 25520 Bottom Glass Retainer 1 8 25521 Top Glass Retainer 1...

Page 19: ...19 Parts Diagram...

Page 20: ...543 6 32 x 3 8 Machine Screw 2 14 83356 10 32 Hex Nut 4 15 83299 6 32 Hex Nut 2 16 891195 Drive Motor Bracket 1 17 25498 Top Lid Weldment 1 18 25511 Left Side Cabinet Weld 5500 1 19 80778 Circuit Boar...

Page 21: ...21 GRAY BLACK Wiring Diagram CORRECT WRONG Ensure the wires are connected to the bottom two prongs of the hopper switch as shown...

Page 22: ...22 Notes...

Page 23: ...23 Notes...

Page 24: ...24 Notes...

Page 25: ...07 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _______________...

Page 26: ...ez toujours le num ro de mod le complet qui se trouve sur la plaque signal tique fix e sur l appareil de chauffage Lors de commandes de pi ces d tach es donnez toujours les informations suivantes tell...

Page 27: ...____________________________ Service de 07 Date _____________________ Nom de l ing nieur ____________________________ N de licence _________________________________ Compagnie _________________________...

Page 28: ...SOSTAT MARRON MARRON NOIR BLANC ROUGE BLEU ORANGE PRISE MOLEX AU CIRCUIT IMPRIM PCB PRINCIPAL NOIR NOIR NOIR BLANC BLANC SOUFFLANTE DE DISTRIBUTION VENTILATEUR D VACUATION THERMISTOR Sch ma de c blage...

Page 29: ...14 83356 crou hexagonal 10 32 4 15 83299 crou hexagonal 6 32 2 16 891195 Support de moteur d entra nement 1 17 25498 Soudure du couvercle sup rieur 1 18 25511 Soudure d armoire c t gauche 5500 1 19 8...

Page 30: ...19 Sch ma des pi ces...

Page 31: ...ion 1 2 25692 poign e porte 1 3 83506 Goupille cylindrique 3 8 x 1 1 4 1 4 891053 porte vitr e 1 5 88066 Joint de corde 5 8 4 5 pi 6 88087 joint en verre 1 x 1 3 16 3 pi 7 25520 support de verre inf r...

Page 32: ...la temp rature de chauffe soit atteinte suivant ce qui a lieu en premier Indicateur Off clignotant Cela indique que le po le est en cours d extinction en attente que le bouton OFF soit press ou penda...

Page 33: ...tirage Assurez vous que la porte d inspection soit ferm e et scell e correctement Si ce n est pas le cas r glez la fermeture de la porte et ou remplacez les joints de la porte V rifiez que tous les r...

Page 34: ...moteurs des ventilateurs d vacuation et de distribution Retirez le ventilateur d vacuation du conduit d vacuation et nettoyez les pales internes du ventilateur lors de votre mise en marche en automne...

Page 35: ...otre po le granul s comprend aussi un allumeur automatique comme accessoire de s rie L utilisation d autres mat riaux d allumage du feu copeaux de bois gel d allumage etc n est pas n cessaire Par une...

Page 36: ...er le Niveau de chaleur Heat Range et la vitesse du ventilateur Blower Speed situ s sur la manette de contr le aux r glages souhait s Remarque La soufflante de distribution ne fonctionnera pas tant qu...

Page 37: ...in se met en marche plein r gime Si le fusible de la vis sans fin n a pas saut et que le circuit de d tection fusible fonctionne le voyant DEL Heat Range du degr de chaleur sera allum et les trois aut...

Page 38: ...atteint la temp rature de fonctionnement En appuyant sur les boutons Room Fan du ventilateur de la pi ce l affichage indiquera Rf A ce qui correspond automatique ou Rf 1 Rf 9 pour les r glages manuels...

Page 39: ...a timer based non continuous cycle this cycling allows the auger to run for a predetermined period of seconds The auger pushes pellets up a chute located at the front bottom of the hopper which in tu...

Page 40: ...AIR FRAIS FIGURE 8 EMPLACEMENTS D VACUATION ARRIV E EXIGENCES SP CIALES POUR MAISON MOBILE INSTALLATION AUX U UNIQUEMENT AVERTISSEMENT Ne pas installer dans une chambre coucher ATTENTION L int grit st...

Page 41: ...onn de la plage de chaleur d sir e 1 5 et le r glage de la plage de chaleur minimale de 1 Le T Stat n allumera ni ne teindra le po le Lorsque la temp rature ambiante souhait e est atteinte et que le T...

Page 42: ...e sous une fen tre ou entre deux fen tres Nous recommandons des kits Simpson Dura Vent ou Metal Fab INSTALLATION TRAVERS LE TOIT PLAFOND Lors de l a ration du po le travers le plafond le tuyau est rac...

Page 43: ...u nuisibles TYPE DE TIRAGE D AIR POUR GRANUL S Un syst me d vacuation de type PL de 3 ou 4 pouces list UL doit tre utilis pour l installation et connect au raccord de conduite fourni au dos du po le u...

Page 44: ...panneau de contr le FIGURE 3 D GAGEMENTS DE LA PAROI LAT RALE INSTALLATION EN PARALL LE FIGURE 4 D GAGEMENTS DE LA PAROI LAT RALE INSTALLATION DANS UN COIN FIGURE 5 D GAGEMENTS DANS UNE ALC VE TABLEA...

Page 45: ...es autres exigences de l installation Une Unit autonome soutenue par un socle pieds et plac e sur un sol non combustible qui respecte les exigences de d gagement d une installation de po le autonome U...

Page 46: ...l inf rieur 300 parties par million Les granul s mous contenant une quantit excessive de sciure de bois en vrac qui ont t ou sont mouill s r duiront les performances Rangez vos pellets dans un endroit...

Page 47: ...avec la porte d inspection ouverte La vis sans fin n approvisionnera pas les granul s dans ces conditions et un probl me de s curit pourrait survenir cause d tincelles ou de fum es qui entreraient dan...

Page 48: ...cet appareil Le non respect de ces instructions peut provoquer des dommages mat riels des blessures personnelles voire la mort Contactez les fonctionnaires locaux de construction ou de lutte contre l...