Summary of Contents for WAIR6

Page 1: ......

Page 2: ...NG 21 4 4 UNPACKING MOUNTING THE DORICA MAIOLICA CASING 21 4 5 UNPACKING MOUNTING THE AROMY CASING 21 4 6 UNPACKING MOUNTING THE AROMY STONE CASING 21 4 7 UNPACKING MOUNTING THE SAINT MORITZ CASING 21 4 8 UNPACKING MOUNTING THE LIENZ CASING 21 4 9 UNPACKING MOUNTING THE MONTREUX CASING 21 4 10 CONNECTING THE APPLIANCE TO THE FLUE OUTLET 21 4 11 DRAWING COMBUSTION AIR FROM OUTSIDE 22 4 12 HANDLE 22...

Page 3: ...io per il riscaldamento domestico senza acqua alimentato a ceppi di legna Residential space heating appliance without water fired by wood logs 4 Nome denominazione commerciale registrata o marchio registrato e indirizzo del fabbricante ai sensi dell articolo 11 paragrafo 5 Name registered trade name or registered trade mark and contact address of the manufacturer as required pursuant Article 11 5 ...

Page 4: ...i esercizio Maximum operating pressure bar Temperatura fumi a potenza termica nominale Flue gas temperature at nominal heat output T 207 C Resistenza meccanica per sopportare un camino una canna fumaria Mechanical resistance to carry a chimney flue NPD Nessuna Prestazione Determinata Potenza termica nominale Nominal heat output 6 06 kW Potenza termica resa in ambiente Room heating output 6 06 kW P...

Page 5: ...ico senza acqua alimentato a ceppi di legna Residential space heating appliance without water fired by wood logs 4 Nome denominazione commerciale registrata o marchio registrato e indirizzo del fabbricante ai sensi dell articolo 11 paragrafo 5 Name registered trade name or registered trade mark and contact address of the manufacturer as required pursuant Article 11 5 THERMOROSSI S P A Via Grumolo ...

Page 6: ...pressure Maximum operating pressure bar Temperatura fumi a potenza termica nominale Flue gas temperature at nominal heat output T 226 C Resistenza meccanica per sopportare un camino una canna fumaria Mechanical resistance to carry a chimney flue NPD Nessuna Prestazione Determinata Potenza termica nominale Nominal heat output 8 53 kW Potenza termica resa in ambiente Room heating output 8 53 kW Pote...

Page 7: ...aldamento domestico senza acqua alimentato a ceppi di legna Residential space heating appliance without water fired by wood logs 4 Nome denominazione commerciale registrata o marchio registrato e indirizzo del fabbricante ai sensi dell articolo 11 paragrafo 5 Name registered trade name or registered trade mark and contact address of the manufacturer as required pursuant Article 11 5 THERMOROSSI S ...

Page 8: ...rking pressure Maximum operating pressure bar Temperatura fumi a potenza termica nominale Flue gas temperature at nominal heat output T 147 C Resistenza meccanica per sopportare un camino una canna fumaria Mechanical resistance to carry a chimney flue NPD Nessuna Prestazione Determinata Potenza termica nominale Nominal heat output 6 52 kW Potenza termica resa in ambiente Room heating output 6 52 k...

Page 9: ...aldamento domestico senza acqua alimentato a ceppi di legna Residential space heating appliance without water fired by wood logs 4 Nome denominazione commerciale registrata o marchio registrato e indirizzo del fabbricante ai sensi dell articolo 11 paragrafo 5 Name registered trade name or registered trade mark and contact address of the manufacturer as required pursuant Article 11 5 THERMOROSSI S ...

Page 10: ...orking pressure Maximum operating pressure bar Temperatura fumi a potenza termica nominale Flue gas temperature at nominal heat output T 143 C Resistenza meccanica per sopportare un camino una canna fumaria Mechanical resistance to carry a chimney flue NPD Nessuna Prestazione Determinata Potenza termica nominale Nominal heat output 8 51 kW Potenza termica resa in ambiente Room heating output 8 51 ...

Page 11: ...zioni legislative che traspongono le seguenti Direttive 2014 30 UE ex 2004 108 CE Direttiva EMC 2014 35 UE ex 2006 95 CE Direttiva Bassa Tensione 2011 65 EU Direttiva RoHS 2 is in accordance with the following Directives 2014 30 EU Directive formerly 2004 108 EC EMC Directive 2014 35 EU Directive formerly 2006 95 EC Low Voltage Directive 2011 65 EU Directive RoHS 2 e che sono state applicate tutte...

Page 12: ...ongono le seguenti Direttive 2014 30 UE ex 2004 108 CE Direttiva EMC 2014 35 UE ex 2006 95 CE Direttiva Bassa Tensione 2011 65 EU Direttiva RoHS 2 is in accordance with the following Directives 2014 30 EU Directive formerly 2004 108 EC EMC Directive 2014 35 EU Directive formerly 2006 95 EC Low Voltage Directive 2011 65 EU Directive RoHS 2 e che sono state applicate tutte le norme e o specifiche te...

Page 13: ...ge can cause serious injury to persons using the appliance DAMAGE TO PROPERTY This safety symbol identifies messages or instructions that are fundamental for the generator to function well To avoid serious damage to the appliance adhere strictly to these instructions INFORMATION This symbol indicates important instructions for good functioning of the appliance If this information is not correctly ...

Page 14: ... in this manual must be carried out when the appliance is cold Attention Warning for Swiss users Refer to the local cantonal regulations imposed by the Fire Department Mandatory signalling and safety distances and the Note concerning installation of heaters issued by the Association of Cantonal Fire Agencies VKF AEAI 1 3 TRANSPORTATION AND STORAGE TRANSPORTATION AND HANDLING The appliance body mus...

Page 15: ...he 1st speed for the WAIR6 and at the 4th speed for the WAIR8 Important take into consideration the fact that the heatable volume is greatly influenced by the insulation of the house i e the energy class of the building and by the position of the appliance in the planimetry of the house The indicated values therefore can vary considerably The data refer to an absorption coefficient of 37 W m3 It i...

Page 16: ...ed for less than 18 20 months as this could be the cause of malfunctions and the formation of tarry deposits that could permanently blacken the walls of the combustion chamber We recommend the use of 250 mm long wood billets load a maximum of 2 3 billets at the time and in any case do not exceed the maximum weight stated in the technical data The fuel feed intervals must not be less than those spe...

Page 17: ...se only the handle provided to move the lever Pulling the Smoke Bypass Device upwards activates the direct bypass of the flue gases whereas pushing the Smoke Bypass Device downwards activates the normal flue gas path D Firebox door When the appliance is operating the door must remain firmly closed and airtight It must only be opened to refuel E Combustion chamber The combustion chamber is made of ...

Page 18: ...Page 18 Installation Use and Maintenance Guide Stove body WAIR6 WAIR6 WITH AIRBOX 1 Stove body WAIR8 WAIR8 WITH AIRBOX 1 ...

Page 19: ...ng oxygen to the appliance 4 2 UNPACKING THE APPLIANCE The appliance is supplied packaged on a pallet before positioning and installing it dismantle the appliance from the pallet as described Remove the cover and the side panels of the pallet A and also the protection panel B Figure 1 Use a screwdriver to undo the 2 screws C see Figure 2 and 3 Remove the protection panel D from the combustion cham...

Page 20: ...Page 20 Installation Use and Maintenance Guide Stove body WAIR6 WAIR6 WITH AIRBOX 1 Stove body WAIR8 WAIR8 WITH AIRBOX 1 ...

Page 21: ...icated chapter Legenda Key Figura Figure Il presente disegno è di proprietà esclusiva di THERMOROSSI S p A La riproduzione totale e o parziale e la divulgazione a terzi senza nostro esplicito consenso scritto verrà perseguito secondo i termini di legge in vigore Tiziano Pegoraro 27 01 2012 PIDRA 14 Scala Locazione file Data Firma Foglio Note Materiale Prodotto Sviluppo PELLET IDRA 14 KW 20 25 TEL ...

Page 22: ...r intake to 80 mm Figure 2 Connect the air intake on the appliance to the exterior of the building with suitable piping The maximum length of the piping is 40 cm 4 12 HANDLE Your appliance is supplied with a handle for opening and closing the firebox door Figure 2 to enable you to refuel the wood and to carry out cleaning operations see dedicated paragraph When not in use the handle can be stowed ...

Page 23: ...t smell It is recommended to ventilate the room until the paint has completely dried 5 1 LIGHTING Before using the appliance check that all the movable parts are correctly fitted Also remove any labels and stickers from the glass to avoid that permanent traces remain on the surfaces Also check that the connection to the flue outlet has been made correctly To startup the stove proceed as follows 1 ...

Page 24: ...el fornitore prima di realizzare qualsiasi attrezzatura fornire a THERMOROSSI S p A i file tridimensionali dei particolari definitivi X IN ACCENSIONE A B RISPARMIO ENERGETICO A B POTENZA NOMINALE 6 A B POTENZA NOMINALE 8 A B WAIR6 Primary air lever Open between the first and second bars Secondary air lever Open on the 2nd bar WAIR8 Primary air lever Open on the 2nd bar Secondary air lever Open on ...

Page 25: ... side of the appliance and the setting options are as follows 100 Front 50 Front 50 Rear 100 Rear Prescriptions for correct channelling It is prohibited to use plastic or internally corrugated pipes It is prohibited to position sections with a downward slope Reduce the number of bends as much as possible maximum 4 To ensure a good result it is obligatory to insulate the pipes Maintain a distance o...

Page 26: ...t to the system to objects and to persons using the appliance Attention do not wet or touch the appliance with wet hands Never vacuum hot ash this could damage the vacuum device All the cleaning operations described in this manual must be carried out when the appliance is cold To clean the glass simply use a damp soft non abrasive cloth and ash The use of any other product is strictly prohibited D...

Page 27: ...Page 27 Installation Use and Maintenance Guide Stove body WAIR6 WAIR6 WITH AIRBOX 1 Stove body WAIR8 WAIR8 WITH AIRBOX 1 ...

Page 28: ...d when the heater is cold using a soft cloth and water The door of the combustion chamber must only be opened when the appliance has completely cooled down when it is opened it is normal for some ash to spill onto the floor ATTENTION after cleaning it is mandatory to carefully check that the combustion chamber door is firmly closed and airtight ATTENTION the generator the smoke channel and flue ou...

Page 29: ...ection indicated above be situated at a height near floor level and they must not obstruct the correct operation of the combustion product discharge devices if this position is not possible the section of the ventilation openings must be enlarged by at least 50 7 3 SMOKE OUTLET The smoke channel the exhaust pipe chimney and flue outlet defined as the system for the evacuation of combustion product...

Page 30: ... are also indicated in the figure below ATTENTION Wall outlets that is outlets installed on the outer front wall without the use of a chimney flue outlet flue pipe to convey the combustion products to the roof are strictly prohibited Components and accessories of a chimney Key 1 Chimney 2 Flow path 3 Smoke discharge tube 4 Thermal insulation 5 External wall 6 Outer lining 7 Flue outlet section 8 M...

Page 31: ...e gases are discharged If you prefer to exhaust the smoke from the roof insert a union tee with inspection cap connecting brackets suitable for the height of the flue outlet flashing that crosses the roof and chimney cap to protect against bad weather conditions LEGENDA KEY COMIGNOLO E CANNA FUMARIA SECONDO NORMA UNI 10683 CHIMNEY CAP AND FLUE OUTLET ACCORDING TO UNI 10683 STANDARD Tutte le tubazi...

Page 32: ...products which tend to accumulate along the discharge path Seal the fittings with red silicone resistant to 350 C The outer casing of the tube must be made with insulating material mineral wool ceramic fiber or use pre insulated tubing THE FLUE OUTLET MUST BE USED ONLY FOR THE APPLIANCE It must be possible to inspect and remove all the smoke tube sections for clean out purposes ATTENTION if the fl...

Page 33: ...Page 33 Installation Use and Maintenance Guide Stove body WAIR6 WAIR6 WITH AIRBOX 1 Stove body WAIR8 WAIR8 WITH AIRBOX 1 ...