background image

ROTISSERIES

Cascade

Gas-Fired Rotisserie with Charbroiler

Installation and  

Operation Manual

woodstone-corp.com

Revised November 2014
Doc no: M0050.01

wood stone corporation

1801 w. bakerview rd.
bellingham, wa 98226 usa

tf. 800.988.8103
t. 360.650.1111
f. 360.650.1166

CASCADE

WS-GFR-6-MB
WS-GFR-10-MB

Summary of Contents for WS-GFR-10-MB

Page 1: ...Charbroiler Installation and Operation Manual woodstone corp com Revised November 2014 Doc no M0050 01 wood stone corporation 1801 w bakerview rd bellingham wa 98226 usa tf 800 988 8103 t 360 650 1111 f 360 650 1166 CASCADE WS GFR 6 MB WS GFR 10 MB ...

Page 2: ...e corp com wood stone corporation 1801 w bakerview rd bellingham wa 98226 usa tf 800 988 8103 t 360 650 1111 f 360 650 1166 TABLE OF CONTENTS TABLE OF CONTENTS CASCADE ROTISSERIE 3 CAUTIONS AND WARNINGS 4 SPECIFICATIONS 6 CLEARANCES VENTING 7 ASSEMBLY 8 UTILITY CONNECTIONS 12 GAS INFORMATION 13 UTILITY INFORMATION 14 CONTROLLER 15 DAILY OPERATION 16 CLEANING THE ROTISSERIE 18 OPTIONAL SPITS 19 PRE...

Page 3: ...t woodstone corp com wood stone corporation 1801 w bakerview rd bellingham wa 98226 usa tf 800 988 8103 t 360 650 1111 f 360 650 1166 CASCADE ROTISSERIE INSTALLATION AND OPERATION MANUAL FOR THE WOOD STONE CASCADE ROTISSERIE CHARBROILER STONE FIRED COOKING EQUIPMENT WS GFR 6 MB 6 SPIT AND WS GFR 10 MB 10 SPIT GAS FIRED ROTISSERIE CHARBROILER ADDITIONAL COPIES AVAILABLE UPON REQUEST WS GFR 6 MB sho...

Page 4: ...iced by authorized professionals DO NOT USE PRODUCTS NOT SPECIFIED FOR USE WITH THIS OVEN WARNING Improper installation adjustment alteration service or maintenance can result in property damage injury or death Read the installation operation and maintenance instructions thoroughly before installing or servicing this equipment IMPORTANT Consult your local gas supplier for a statement outlining a p...

Page 5: ...nd is ETL Listed to ANSI Z83 11b 2009 CSA 1 8b 2009 and to NSF ANSI Standard 4 2009 WHEN THE OVEN IS NOT PROPERLY INSTALLED A FIRE MAY RESULT TO REDUCE THE RISK OF FIRE FOLLOW THE INSTALLATION INSTRUCTIONS A MAJOR CAUSE OF FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES AIR SPACES TO COMBUSTIBLE MATERIALS IT IS OF THE UTMOST IMPORTANCE THAT THIS APPLIANCE BE INSTALLED ONLY IN ACCORDANCE WITH THES...

Page 6: ...U hr Natural Gas NG OR 185 000 BTU hr Propane LP Broiler Gas 1 inch FNPT gas inlet 152 000 BTU hr Natural Gas NG OR Propane LG Maximum gas inlet pressure 1 2 psi 14 inches W C Electrical 120 VAC 5 A 50 60 Hz Water Inlet 1 4 FNPT Drain 1 1 2 outlet tube All utility connections made on the bottom of the unit NEMA 5 15 plug Refer to data plate when installing Shipping Weight 2 000 lbs Venting The Cas...

Page 7: ...ck required air spaces with insulation or other material Do not obstruct the flow of combustion and ventilation air VENTING The Wood Stone Cascade Gas fired Rotisserie must be vented using a Listed Type 1 exhaust hood or one constructed in accordance with the Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations NFPA 96 and all relevant local and national codes and ...

Page 8: ...LE APPLIANCES When this appliance is installed with casters it must be installed with the casters supplied a connector complying with either ANSI Z21 69 or CSA 6 16 and a quick disconnect device complying with ANSI Z21 41 or CSA 6 9 It must also be installed with restraining means to guard against transmission of strain to the connector as specified in the appliance manufacturer s instructions ATT...

Page 9: ...ct the two bottom rails of the charbroiler table to the corresponding bottom rails of the rotisserie cabinet See the illustration below for the correct installed location of the Connector Plate Part A STEP 4 CONNECT FLEXIBLE ELECTRICAL HARNESS a Remove the Service Panels on the Controller side of the rotisserie cabinet and locate the yellow flexible electrical cable b Remove the Controller Plate f...

Page 10: ...ater knob to the OFF position STEP 7 INSTALL CONNECTION FLASHING BETWEEN THE CHARBROILER AND THE ROTISSERIE Install the stainless steel flashing pieces provided to cover the space between the rotisserie and the charbroiler and also between the Charbroiler and the controller housing No fasteners are required to hold the pieces in place See the picture at left for the proper positioning of the flash...

Page 11: ...98226 usa tf 800 988 8103 t 360 650 1111 f 360 650 1166 ASSEMBLY STEP 8 APPLY HIGH TEMPERATURE SILICONE SEALANT Use the high temperature silicone sealant provided to fill spaces between the charbroiler and the rotisserie cabinet Also seal the seams between the legs and the cabinet Use the high temperature silicone sealant provided to seal the charbroiler flashing to the controller housing of the c...

Page 12: ...er line fitted with a 1 4 MNPT connector DRAIN TO FLOOR SINK GREASE TRAP A 1 1 2 drain outlet tube at the bottom of the rotisserie is provided This outlet must be connected to an indirect waste pipe and discharge by means of an air gap in accordance with all applicable plumbing codes The indirect waste pipe should discharge into a drain system that is serviced by a grease trap GAS CONNECTION Suppl...

Page 13: ...tween the rotisserie and the main gas supply and be left readily accessible ROTISSERIE BURNER PRESSURE TESTING There are 2 pressure test ports one for each burner located on the respective valves The valve outlet pressures have been adjusted and tested at the factory A variety of factors can influence these pressures so be sure to test the valve outlet pressures and adjust the valves as necessary ...

Page 14: ...of that system at test pressures in excess of 1 2 psi 3 45 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve supplied by others during any pressure testing of the gas supply piping system at test pressure equal to or less than 1 2 psi 3 45 kPa Wood Stone recommends that the appliance s individual shutoff valve supplied by others loc...

Page 15: ...MINUTES BEFORE ATTEMPTING TO RELIGHT THE BURNERS GREEN Starts rotisserie drum when rear doors are open depressing the button will jog the drum YELLOW Lights both burners rotisserie drum must be activated before burners will light Water valve knob Gas throttle knob BLACK Rotisserie drum speed control knob RED Stops both burners and rotisserie drum GREEN Starts rotisserie drum when rear doors are op...

Page 16: ...ke certain product does not hit the back wall or the optional smoker box as the drum turns Note drum rotates from the bottom up NEVER ATTEMPT TO PLACE OR REMOVE SPITS WHEN THE ROTISSERIE DRUM IS MOVING BURNERS WON T TURN ON IF DRUM IS NOT TURNING LOADING THE SPITS EVENLY The spits can only be inserted into the rotisserie drive one way When loading the rotisserie make sure the load is evenly distri...

Page 17: ...urning it to the right will increase the speed For most cooking situations setting the knob at the midpoint with the white indicator line straight up is a good place to start STOPPING THE DRUM ROTATION AND BURNERS There are three ways to stop the drum rotation and burners 1 Push the RED button on the front controller 2 Push the RED button on the rear controller 3 Open the rear door TO RESTART THE ...

Page 18: ...pray water onto or around the burners or into either of the side compartments on the rotisserie CLEANING THE ROTISSERIE CABINET EXTERIOR All exposed surfaces of the rotisserie should be wiped clean daily using an approved mild cleaning solution Stubborn residues may be removed using a non metallic scouring pad When scouring stainless steel scrub with the grain to avoid scratching the finish DO NOT...

Page 19: ...inless steel and conveniently adjusts to hold a variety of products ranging from fresh vegetables to two entire prime ribs Stainless steel screens are also available to help secure smaller items Includes Chain Assembly for Clamshell Basket locking mechanism D RIB FISH BASKET SPIT The Rib Fish Basket Spit is available in a 3 arm 6 compartment or in a 4 arm 8 compartment models Each compartment is s...

Page 20: ...ed and requires no additional maintenance SPUR GEAR BUSHING Check the spur gear bushings for signs of binding or lateral movement where the gear shank passes through the drive end drum The gear should rotate in the Rulon inner bushing If the gear and Rulon bushing are rotating in the drum sleeve instead remove the gears and Rulon bushings clean and refit Do not lubricate the bushings or gears To r...

Page 21: ...o M0050 01 info woodstone corp com or visit woodstone corp com wood stone corporation 1801 w bakerview rd bellingham wa 98226 usa tf 800 988 8103 t 360 650 1111 f 360 650 1166 ELECTRICAL DIAGRAMS USED ON ALL MODELS WITH DUAL FRONT REAR CONTROLS These electrical schematic diagrams can also be found affixed to the inside of the drive side Service Panel of the rotisserie Front panel Rear panel ELECTR...

Page 22: ... WS GFR MB Revised November 2014 Doc no M0050 01 info woodstone corp com or visit woodstone corp com wood stone corporation 1801 w bakerview rd bellingham wa 98226 usa tf 800 988 8103 t 360 650 1111 f 360 650 1166 ELECTRICAL DIAGRAMS ELECTRICAL LINE DIAGRAM This electrical line diagram can also be found affixed to the inside of the drive side Service Panel of the rotisserie ...

Page 23: ...ced under normal conditions 7 In the event that pressed log products of any type have been burned in the equipment If any oral statements have been made regarding this appliance such statements do not constitute warranties and are not part of the contract of sale This Limited Warranty constitutes the complete final and exclusive statement with regard to warranties THIS LIMITED WARRANTY IS EXCLUSIV...

Reviews: