background image

 

Summary of Contents for Genova 90

Page 1: ......

Page 2: ...User Manual BUILT IN GAS STOVE GENOVA 90 1 1 INTRODUCTION 2 2 SECURITY WARNING 3 3 HOW TO USE YOUR STOVE 5 4 HOW TO TAKE CARE OF YOUR GAS STOVE 6 5 INSTALLATION 9 6 SPECIFICATIONS TABLES 15 ...

Page 3: ...contact our customer service center The manufacturer shall not be responsible for any damages to persons or property caused by improper installation or misuse of your kitchen The artifact has been certified for use in countries other than those marked at the stove The manufacturer reserves the right to make any modifications to the products as may be considers necessary or useful also in the inter...

Page 4: ...xiliary burner 2 Semi rapid burner 3 Triple ring wok burner 4 Control Knobs for Gas Burners and Electric Hot Plates 5 Ignitor for Gas Burners 6 Safety Device Activates if the flame accidentally goes out spills drafts etc interrupting the delivery of gas to the burner ...

Page 5: ...UILT IN GAS STOVE GENOVA 90 4 MODELS GENOVA 90 Cooking Zone 5 Voltage 110 240V 50 60Hz Total Power 8 60kW Front Side control operation YES Product Size D W H mm 870 x 510 x 100 Cut Out Dimensions D x W mm 840 x 480 ...

Page 6: ...rning off when you turn it on since your account has a safety valve To light a burner simply press the corresponding knob and turn it counterclockwise to the High setting press and hold until the burner ignites Caution If the flame accidentally goes out turn off the gas with the control knob and try to turn it on again at least 1 minute later To turn off a burner Turn the knob clockwise until it s...

Page 7: ...e shelf life we recommend you rinse these parts thoroughly with water and dry them by blowing It is also a good idea to clean up any spillage After working the glass plate the surface should be cleaned with a damp cloth to remove dust or food debris The glass surface should be cleaned regularly with warm water and non corrosive detergent First to remove all food or grease residues with a cleaning ...

Page 8: ... gas valves can get stuck and it is difficult to turn on off For this case you must clean the inside of the valve and grease it Kind Reminder This procedure must be performed by a technician authorized by the manufacturer Practical advice Practical advice on the use of burners For best performance follow these general guidelines Use the appropriate cooking utensils for each burner see table to pre...

Page 9: ...There is no air flow around the cooking surface The flame does not keep the burner burning with thermocouple check to make sure that Press the knob completely Keep pressing the knob for long enough to activate the thermocouple Gas holes are not obstructed in the area corresponding to the thermocouple The flame goes out when the knob is turned to the Low setting check to make sure that Gas holes ar...

Page 10: ...nt ventilation The following requirements must be met a The room must be equipped with a ventilation system that ventilates smoke and combustion gases outside the rooms This should be done by hood or electric fan In a fireplace or fireplace Directly outside branched exclusively for kitchen appliances b Air must be allowed for adequate combustion The air flow for combustion purposes must not be les...

Page 11: ...empty or partially filled should not be installed or stored in rooms or spaces below ground level warehouses etc It is a good idea to keep only the tank currently operating in the room and make sure it is not closed to the heating source ovens fireplaces stoves etc Installation of the built in gas stove The gas plates are designed with a degree of protection against excessive heating the device ca...

Page 12: ...he plate must be installed directly under a cabinet the latter must be at least 700 mm from the worktop as shown in Fig C e Fixing accessories hooks screws are provided to place the plate on the top of the table measuring 20 to 40 mm thick see Fig 6 ...

Page 13: ... of at least 45 x 560 mm from the back When installing a plate in a built in oven without forced ventilation be sure to have air inlets and outlets to properly ventilate the interior of the cabinet Gas connection for gas hob The gas plate must be connected to the gas supply by a registered installer During installation it is essential to install an approved gas tap to isolate the supply of the pla...

Page 14: ...rtop is threaded 1 2 connector for round gas pipe Use only pipes and sealing gaskets that meet current standards The maximum length of flexible pipes must not exceed 2000 mm Once the connection has been made make sure that the flexible metal tube does not touch any moving parts and does not crush Check the seal Once the plate is installed make sure all connections are properly sealed use soapy wat...

Page 15: ... by the board The power supply system is equipped with an efficient ground connection in accordance with the rules and regulations prescribed by law The plug or switch is easily accessible Important the cables in the main cable are colored according to the following code Green and Yellow Earth Blue Neutral Brown Live Since the colors of the wires in the main wire may not correspond to the colored ...

Page 16: ...P C I G30 49 47MJ Kg Replacement of burner nozzle loosen the nozzle with a dedicated wrench 7 Fit the new nozzle according to the required gas type see table 1 for reference After you have converted the gas hob to another gas type make sure you have placed a G20 G30 Burner Thermal power kW Nozzle 1 100 mm Thermal power kW Nozzle 1 100 mm Auxiliary Small A 1 0 71 1 0 52 Semi rapid Medium 1 80 97 1 ...

Page 17: ... flame Loosen the adjustment Spindle see fig 7 below And adjust the flame Valve adjustment Valve adjustment should be done with the control knob set at Burner ON saving flame position Remove the knob and adjust the flame with a tiny screwdriver see fig 7 below Fig 7 To check the adjusted flame heat the burner at full open position for 10 minutes Then turn the knob into the saving setting The flame...

Page 18: ...Up to 60 are conserved when proper pots are used Up to 60 are conserved when the unit is operated correctly and the suitable flame size is chosen It is a prerequisite for efficient and energy saving operation of hob that the burners are kept clean at all times in particular the flame slots and nozzles Adapting to different types of gas Adaptation to different types of gas APPLIANCE CATEGORY I2H I2...

Page 19: ...ssification label C This gas plate is not connected to the combustion products evacuation device It will be installed and connected in accordance with current installation regulations Special attention will be given to the relevant requirements regarding ventilation D CAUTION The use of a gas plate leads to the production of heat humidity and combustion products in the room in which it is installe...

Reviews: