Function Description Related to Records
42
Chapter
7
Selected data is recorded in the UPM100 unit.
As for details on records, items set on record item setting 1 and 2 of the record setting mode are
saved.
As for point data and alarm detection data, items set on record item setting 1 and 2 are saved.
The items are sequence number, date and time, voltage (each interphase and average interphase),
current (each phase, average phase), electric power (effective, reactive, apparent), two sets of UTM
Ⅱ
(torque, rotation speed, driving force), efficiency, power factor, two sets of ID numbers, two
AUX, two temperature, and record factor.
A maximum of 27 items can be recorded with one point of data.
Both point data and alarm detection data will be deleted when the power is turned off or if data
deletion is executed.
Point data
1000 points of data can be recorded.
The recording is done at timings such as key and external input, RS-232C commands and so on.
The most recent 1000 points of data is retained.
Alarm detection data
All indicated values in between seven seconds before and three seconds after the alarm detection
are recorded.