Universal unipo® Flat Panel UFP
Malfunctions
80
Revision status 19.01.2010
8.4 Faults – device messages
Device messages
Cause
Remedy
Graphics board defective
Replace graphics board
Cable defective
Replace cable
Control not starting up
Start up, repair control
Wrong I-module
Replace I-module
see chapter "Technical
information"
No image,
but OSD present
Video cable plugged in
wrong (only BNC)
Connect cable correctly
Check video cable
Missing H-Sync
Replace graphics board
No H-Sync found.
Please check your
video source
Wrong I-module
Replace I-module
Check video cable
Missing V-Sync
Replace graphics board
No V-Sync found.
Please check your
video source
Wrong I-module
Replace I-module
Deactivate screensaver of
control
Check video cable
UFP does not receive
video signal
Replace graphics board
Screensaver active
Wrong I-module
Replace I-module
Table 16: Faults - device messages
Summary of Contents for UFP 6"
Page 3: ...Operating manual Universal unipo Flat Panel UFP Revision status 19 01 2010...
Page 14: ...Universal unipo Flat Panel UFP General 12 Revision status 19 01 2010...
Page 18: ...Universal unipo Flat Panel UFP Safety 16 Revision status 19 01 2010...
Page 30: ...Universal unipo Flat Panel UFP Design of the UFP 28 Revision status 19 01 2010...
Page 76: ...Universal unipo Flat Panel UFP Software description 74 Revision status 19 01 2010...
Page 84: ...Universal unipo Flat Panel UFP Repair 82 Revision status 19 01 2010...
Page 86: ...Universal unipo Flat Panel UFP Glossary 84 Revision status 19 01 2010...
Page 88: ...Universal unipo Flat Panel UFP Appendix Technical data sheets 86 Revision status 19 01 2010...
Page 90: ...Universal unipo Flat Panel UFP List of tables 88 Revision status 19 01 2010...
Page 96: ...Universal unipo Flat Panel UFP Index 94 Revision status 19 01 2010...