60
On
— the scanner checks the weather channels every 5 seconds for a 1050 Hz weather alert signal. Press the Scroll Control to
select.
Off
— the scanner does not check the weather channels. This is the default setting. Press
◙
to select.
Notes:
•
You can also turn this option on and off by pressing the front-panel WX key.
•
When you turn on this option, you will notice a break in the audio every 5 seconds as the scanner checks for the weather
alert signal.
Fire Tone-Out Introduction
Your scanner can be set to respond to fire tone-outs, a system comprised of standardized two-tone sequential paging, short one-
tone paging, and long group tone paging. You can save up to 10 settings. When you select a setting in standby mode, the scanner
also monitors for any other setting that uses the same transmit frequency, modulation, and attenuation settings.
You need tone-out setup information from the agency you wish to monitor. Check with your local agency or on-line resources as
Uniden America Corporation has no information regarding local tone-out systems.
Setting Tone-Out Standby
[MENU]
Tone-Out for...
◙
Tone-Out Standby
◙
Turn the Scroll Control
to select which of the ten tone-outs to monitor. All tone-outs that have the same frequency, modulation,
and attenuation setting as the one you select, are also monitored.
In standby mode, the display cycles through all monitored tone-out settings. Regardless of the current display, the scanner always
alerts on any received tone-out that matches a stored setting.
If you press
[HOLD/RESUME]
while in standby mode, the scanner temporarily exits the mode and you hear all transmissions on that
frequency. No alerts sound, even if a tone-out matches one you have stored. Press
[HOLD/RESUME]
again to return to standby
mode.
Setting Up Tone-Out
[MENU]
Tone-Out for...
◙
Tone-Out Setup
◙
Scroll to select the tone-out (1 - 10) you want to program, then press
◙
.
Then you can scroll to any of the following settings and
press
◙
to select and modify the selected settings:
Edit Name
— Sets the name for the selected tone-out setting.
Set Frequency
— Sets the tone-out’s RF frequency parameters. Then select:
•
Edit Frequency
— Enter the desired frequency that the scanner should monitor for the tone-out.
•
Set Modulation
— Set the modulation type for the paging signal. Next choose the modulation setting:
Auto
—The scanner uses the default modulation for the frequency band. If the default modulation is AM, WFM,
or FMB, the modulation operates as FM.
FM
— The scanner uses FM for the frequency band. This is the default setting.
NFM
— The scanner uses NFM modulation.
Set Attenuation
—
Turn the Scroll Control to select
On
or