9
Technical features and dimensions
2.4 - HYDRAULIC CIRCUIT
2
3
5
7
6
1
- Zone valve
2
- Drain cock for boiler and
M 3000 S
3
- Mixing bottle
4
- Primary circuit boiler flow adjuster
5
- Automatic air vent
6
- Inlet temperature sensor (at)
7
- Motorized mixing valve
8
- Circulating pump for floor heating
circuit
9
- Outlet flow temperature sensor (m)
9
- Manual rest limit thermostat (60°C)
R
= Boiler Return
M
= Boiler Flow
R 1
= Radiator circuit return
(high temperature)
M1
= Radiator circuit flow
(high temperature)
Rm
= Low temperature floor heating
circuit Return (mixed water)
Mm
= Low temperature floor heating
circuit Flow (mixed water)
4
8
9
10
1
R1
Rm Mm
R
M
M1
2.5 - MAIN FEATURES
Max. output available on the mixed circuit
with t 5 °C (Flow temp. 40 °C)
Max output available on the mixed circuit
with t 10 °C (Flow temp. 40 °C)
Heat losses of the Thermal Module
Electrical supply Tension/Frequency
Main Fuse
Maximum absorbed power
Protection degree
Gross weight
kW
kW
W
V-Hz
A (F)
W
IP
kg
M 3000 S
9,3
14
106,8
230/50
??
93
20
??
M 3000 S inc
9,3
14
106,8
230/50
??
93
20
??
Summary of Contents for M 3000 S
Page 1: ...INSTALLATION AND SERVICING INSTRUCTIONS GB 00333624 1st edition 09 10 M 3000 S ...
Page 33: ...33 ...
Page 34: ......
Page 35: ......