Instruction for the installer
Connection of the outer sensor
To be performed on the terminals
EXT SENSOR;
the scree-
ning, if present, has to be connected to the terminal
SHIELD
.
BOILER
(OT / +)
EXT
SENSOR
SHIELD
ROOM
STAT / NS
OV
BUS -
BUS +
BOILER
(TA)
Outer
sensor
SND0140C
Room temperature adjustment
- OUTER SENSOR
Solution suggested for floor heating systems
- TIMER + OUTER SENSOR
Solution that allows the weather compensation and the
night reduction
- REGOLA OUTER SENSOR
Solution that allows the weather compensation, the room
temperature compensation, the remote control and the
night reduction; it is suggested for every type of application.
- TA on-off (On-Off Room thermostat) + OUTER SENSOR
Solution that allows the weather compensation, the room
temperature compensation; it is essential for a multi-zone
installation. (A thermal module that manages several low
temperature zones through several zone valves and a high
temperature zone).
Outer Sensor
The outer sensor (code SND0140C) is tandard supplied with
the M 3000 S.
Also in case of installation with more thermal
modules,
just one outer sensor,
to be con-
nected to the main module (MASTER) is
enough.
Position the outer sensor from 2.5 m from the ground, on a
wall NORTH/NORTH-EAST oriented, protected from the sun
and the predominant winds.
To avoid electromagnetic disturbances it is ne-
cssary to separate the harness between outer
sensor and the M 3000 S terminal strip from
230 V harness.