BOARDA 00630130
BOARD 00630132
BOILER
1
2
3
4
ON
Y2
LINE
NEUT
JP
2
Y3
Y1
JP
1
BOARD 00630130
BOARD 00630132
BOILER
1
2
3
4
ON
Y2
LINE
NEUT
JP
2
Y3
Y1
JP
1
BOARD 00630130
BOARD 00630132
YELLOW
BOILER
BLUE
PURPLE
BOILER
(OT / +)
EXT
SENSOR
SHIELD
ROOM
STAT / NS
OV
BUS -
BUS +
BOILER
(TA)
RED
BLACK
BLUE
WHITE
BROWN
GREEN
GRAY
1
2
3
4
ON
BOILER
(OT / +)
ROOM
STAT / NS
OV
BUS -
BUS +
BOILER
(TA)
M3000
MODULO 1
PRINCIPALE
MASTER
BOILER
(OT / +)
ROOM
STAT / NS
OV
BUS -
BUS +
BOILER
(TA)
BOILER
(OT / +)
ROOM
STAT / NS
OV
BUS -
BUS +
BOILER
(TA)
ROOM
STAT (230 V) N
L1
To the boiler
Outer sensor
ROOM
STAT (230 V) N
L1
ROOM
STAT (230 V) N
L1
ROOM
STAT (230 V) N
L1
Y2
LINE
NEUT
(low temperature)
- TA ON-OFF
- REGOLAFACILE
- TIME CLOCK
- Limit stop contact of zone valves
EXT
SENSOR
SHIELD
EXT
SENSOR
SHIELD
EXT
SENSOR
SHIELD
(low temperature)
- TA ON-OFF
- REGOLAFACILE
- TIME CLOCK
- Limit stop contact of zone valves
(low temperature)
- TA ON-OFF
- REGOLAFACILE
- TIME CLOCK
- Limit stop contact of zone valves
(low temperature)
- TA ON-OFF
- REGOLAFACILE
- TIME CLOCK
- Limit stop contact of zone valves
YELLOW
BLUE
PURPLE
RED
BLACK
BLUE
WHITE
BROWN
GREEN
GRAY
YELLOW
BLUE
PURPLE
RED
BLACK
BLUE
WHITE
BROWN
GREEN
GRAY
YELLOW
BLUE
PURPLE
RED
BLACK
BLUE
WHITE
BROWN
GREEN
GRAY
3.14 - ADJUSTMENT OF M 3000 IN
COMPLEX INSTALLATIONS
Cascade connection of several M 3000 S
The application of M 3000 S in complex installations requi-
res the designation of a main module (MASTER) and se-
condary modules (SLAVE).
SETTINGS OF THE MAIN MODULE (MASTER)
Once the settings of the
(A) switches
1-2-3-4 on the main
module
(MASTER)
have been completed, it is necessary to
modify through the
REGOLAFACILE
the parameter
07
‘’num-
ber of secondary modules connected (SLAVE)’’.
Change the value according to the number of secondary mo-
dules connected (in this case
3
); follow the procedure for the
parameter modification described in the chapter 3.11.
SETTINGS IN SECONDARY MODULES (SLAVE)
(suitable for configurations up to 3 slave modules)
Set the switches as shown in
B - C - D
.
A
Switch Setting
Description
1
ON
Heating function (do not modidy
2
ON
Module MASTER ON
3
ON Boiler with data communication capacity
OFFBoiler without data communication capacity
Sub-parameter
Name
Factory
Value
Regolafacile
settings
07
Hn
0
1 ÷ 13
The functionality of switch 4 depends on the position of switch 3
Switch Setting
Description
3
ON
Boiler with data communication capacity
4
ON Direct data connection between M3000 & boiler
OFF Data connection via PCB 00630083
Switch Setting
Description
3
OFF
Boiler controlled in ON/OFF mode
4
ON The boiler temperature is controlled by M3000
(Es. Caldaie in acciaio)
OFF La temperatura è controllata dalla caldaia
(es. caldaie murali).
1 2 3 4
ON
B
C
D
1 2 3 4
ON
1 2 3 4
ON
SLAVE 1 (B)
SLAVE 2 (C)
SLAVE 3 (C)
up to 4 M 3000 S + boiler
Warning
!
Observe the polarity:
OV / OV
BUS - / BUS -
BUS + / BUS +
Summary of Contents for M 3000 S