background image

Prestige

Display Module  Replacement 

1

WARNING

!

Indicates a potentially hazardous situation which, 
if ignored, can result in serious  injury or substan-
tial property damage.

NOTICE

Indicates special instructions on installation, operation 

or maintenance, which are important to equipment 

but not related to personal injury hazards.

WARNING

!

For your safety, turn off electrical power supply 
at service panel and allow unit to cool before pro-
ceeding to avoid possible electrical shock and 
scald hazard.  Failure to do so can cause severe 
personal injury or death.

WARNING

!

Failure to follow instructions below can result in 
severe personal injury or damage if ignored.

•  Instructions are for a qualified installer/ ser-

vice technician only.

•  Read all instructions before proceeding.
•  Follow instructions in proper order.

Each Kit Includes:

•  Display Module

•  (6) Screws 

Recommended Tools:

•  Flathead Screwdriver

•  Phillips Head Screwdriver 

Kit Part Number

Description

Model

PARKIT101

Display Module Replacement

All Models

2020-20 Prestige Display Module Replacement

Revised 1/22/2020

Summary of Contents for Prestige PARKIT101

Page 1: ...ore pro ceeding to avoid possible electrical shock and scald hazard Failure to do so can cause severe personal injury or death WARNING Failure to follow instructions below can result in severe personal injury or damage if ignored Instructions are for a qualified installer ser vice technician only Read all instructions before proceeding Follow instructions in proper order Each Kit Includes Display ...

Page 2: ...s and document the boiler s settings This will ensure any settings revised from factory defaults are transferred to the new module s Use Table 1 to record the existing settings Do not revise any settings when recording settings 1 To access the parameter screen press the round in staller button as shown in Fig 1 Fig 1 Installer Button 2 Enter the installer access code 054 by using the LEFT and RIGH...

Page 3: ... Screen icon then press the OK button NOTICE Perform the following steps if the Instinct is part of a Cascade System or the System Temperature Sensor is being used on a single Instinct 11 Press the RIGHT then DOWN buttons to highlight the Previous Screen icon then press the OK button 12 Press the RIGHT then DOWN buttons to highlight the Cascade icon then press the OK button 13 Press the RIGHT butt...

Page 4: ...nel to the boiler 6 Turn power to the unit ON and return the boiler to service 5 Programming new Control Board 1 Follow the instructions in step 2 to gain access to the installer menu 2 Go to boiler settings and click appliance setting as seen in Fig 9 and Fig 10 Fig 9 Installer Menu Fig 10 Appliance setting 3 The required code is written on the data plate lo cated at the side of the boiler Use th...

Page 5: ...ff Off 78 F 25 C Circulation Pump Permanent Disabled CH Post Pump Time 5 Minutes Off 20 Minutes Freeze Protection Enabled Frost Protection Setpoint 22 F 30 C 22 F 30 C 50 F 10 C Parallel Shift Value 0 F 0 C 0 F 0 C 144 F 80 C CH Call Blocking 2 Minutes 0 Minutes 30 Minutes DOMESTIC SETTING FACTORY DEFAULT MINIMUM SETTING MAXIMUM SETTING EXISTING SETTING DHW Operation Enabled Demand Type Thermostat...

Page 6: ...Relay On Lockout Blocking and Warning Pump PWM Minimum 30 1 100 Ignition Level Varies by model Mix Zone High Limit 114 F 45 C 68 F 20 C 176 F 80 C Appliance Setting Varies by model CASCADE SETTING FACTORY DEFAULT MINIMUM SETTING MAXIMUM SETTING EXISTING SETTING Stage Delay 60 Seconds 0 Seconds 255 Seconds Minimum Firing Rate 18 0 100 Max Firing Rate Varies by model 0 MBH 0kW 869 MBH 255kW CH DHW B...