background image

USER GUIDE

LOGIC 

CODE COMBI ESP1

26 33 38

When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance 

specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by Ideal.

For the very latest copy of literature for specification and maintenance practices visit our website www.idealboilers.com  

where you can download the relevant information in PDF format.

For alternative languages in our User Guides please visit our website 

www.idealboilers.com

.

February 2018

UIN 215347 A06

Summary of Contents for LOGIC CODE COMBI ESP1 26

Page 1: ...uire Do not use reconditioned or copy parts that have not been clearly authorised by Ideal For the very latest copy of literature for specification and maintenance practices visit our website www idealboilers com where you can download the relevant information in PDF format For alternative languages in our User Guides please visit our website www idealboilers com February 2018 UIN 215347 A06 ...

Page 2: ...o the current ETCI rules for electrical installation It is essential that the instructions in this booklet are strictly followed for safe and economical operation of the boiler ELECTRICITY SUPPLY This appliance must be earthed Supply 230 V 50 Hz The fusing should be 3A IMPORTANT NOTES This appliance must not be operated without the casing correctly fitted and forming an adequate seal If the boiler...

Page 3: ...ler fails to light after five attempts the fault code will be displayed refer to Fault Code page OPERATION MODES Winter Conditions Central Heating and Domestic Hot Water required Set the mode knob C to winter The boiler will fire and supply heat to the radiators but will give priority to domestic hot water on demand Summer Conditions Domestic Hot Water only required Set the mode knob C to summer S...

Page 4: ...nob towards the MAX position to meet heating requirements This will depend on the house and radiators used Reducing the room thermostat setting by 1ºC can reduce gas consumption by up to 10 WEATHER COMPENSATION When the Weather Compensation option is fitted to the system then the central heating temperature knob B becomes a method of controlling room temperature Turn the knob clockwise to increase...

Page 5: ... made before it fully defrosts Warm water can also be poured onto the pipe from a watering can or similar DO NOT use boiling water 3 Caution when using warm water as this may freeze and cause other localised hazards 4 Once the blockage is removed and the condensate can flow freely restart the appliance Refer to To Light the boiler 5 If the appliance fails to ignite call your Gas Safe Registered en...

Page 6: ...the time settings on the programmer are as you require and adjust if necessary Check the programmer internal or external to the boiler is in an ON position and the room thermostat is turned up NO HOT WATER OR CENTRAL HEATING Check the mains power is turned on and ensure mode knob C is in the winter position See boiler Operation Modes and Fault Codes section Does the boiler have a display showing o...

Page 7: ...he boiler The boiler is operating in central heating mode The boiler is operating in domestic hot water mode The boiler is operating in frost protection 7 NORMAL OPERATION DISPLAY CODES The boiler mode knob C is in the off position rotate fully clockwise for hot water and central heating operation FP 54 54 00 54 54 o C o C o C o C FOR ANY QUERIES PLEASE RING THE IDEAL CONSUMER HELPLINE 01482 49866...

Page 8: ...arranty or alternatively a Gas Safe Registered Engineer if outside of the warranty period In IE contact a Registered Gas Installer RGII 1 Check condensate pipe for blockages refer to Section 4 2 Check other gas appliances in the house are working to confirm a supply is present in the property 3 If other appliances do not work or there are no other appliances check the gas supply is on at the meter...