USERS GUIDE

LOGIC +

Heat

12, 15, 18, 24, 30

When replacing any part on this appliance, use only spare parts that you can be
assured conform to the safety and performance specification that we require.  
Do not use reconditioned or copy parts that have not been clearly authorised by Ideal.

For installation guide see reverse of book 

Summary of Contents for Logic 12

Page 1: ...t on this appliance use only spare parts that you can be assured conform to the safety and performance specification that we require Do not use reconditioned or copy parts that have not been clearly authorised by Ideal For installation guide see reverse of book ...

Page 2: ...rried out by a Registered Gas Installer RGII and installed in accordance with the current edition of I S 813 Domestic Gas Installations the current Building Regulations and reference should be made to the current ETCI rules for electrical installation It is essential that the instructions in this booklet are strictly followed for safe and economical operation of the boiler Electricity Supply This ...

Page 3: ...om temperature Once the desired setting has been achieved leave the knob in this position and the system will automatically achieve the desired room temperature for all outside weather conditions To Shut Down the Boiler Set the mode control knob to OFF To Relight the Boiler Repeat the procedure detailed in To light the boiler E 205862 10090 Frost Protection If no system frost protection is provide...

Page 4: ...dip in the pipe in which condensate can collect The location of the blockage should be identified as closely as possible before taking further action 2 Apply a hot water bottle microwaveable heat pack or a warm damp cloth to the frozen blockage area Several applications may have to be made before it fully defrosts Warm water can also be poured onto the pipe from a watering can or similar DO NOT us...

Page 5: ...rior to requesting a service engineers visit Should the problem be found to be other than with the appliance we reserve the right to levy a charge for the visit or for any pre arranged visit where access is not gained by the engineer Troubleshooting NO CENTRAL HEATING OR HOT WATER Check the mains switch fused spur is turned on and ensure mode control knob B is in the ON position Does the boiler op...

Page 6: ... between 1 1 5bar on the pressure gauge If the boiler fails to operate then please contact Ideal if under warranty or alternatively a Gas Safe Registered Engineer if outside of the warranty period In IE contact a Registered Gas Installer RGII Flame Loss See Action Fault Code L 2 Fan Fault Reset the appliance if the boiler fails to operate then please contact Ideal if under warranty or alternativel...

Page 7: ...7 Ideal Logic Heat User s ...

Page 8: ...1482 448858 Registration No London 322 137 Ideal Stelrad Group pursues a policy of continuing improvement in the design and performance of its products The right is therefore reserved to vary specification without notice Ideal Consumer Helpline Tel 01482 498660 www idealheating com ...