9
Operating site
For proper operation and satisfying distribution of
the temperature the heat stove must be placed
in premises where the air required for pellet
combustion may flow (about 40 m
3
/h must be
available according to installation regulations and
standards in force in the country). The volume of
the room must not be less than 30 m
3
.
The air must enter through permanent openings
on the walls (near the stove) to the outside with
minimum section greater than 120 cm
2
.
These openings must be protected by a grille
both inside and outside and constructed so as
not to be obstructed in any way.
The air may also be taken from rooms adjacent
to the one to be ventilated as long as they are
equipped with external air intake and are not used
as bedroom or bathroom and where there is no fire
hazard such as: garage, wood sheds, flammable
material warehouses in strict compliance with the
current rules.
Installation of the heat stove is
not permissible in bedrooms,
bathrooms, and where another
heating appliance is already installed
without independent air inflow (fireplace,
stove etc.).
It is forbidden to place the stove in premises
with explosive atmosphere. The floor of the
premises where the stove is to be installed
must be suitably sized to withstand its
weight.
In the event of flammable walls maintain a
minimum rear distance (A) of 10 cm, side
(B) of 40 cm and front of 150 cm. In the
event of especially delicate objects such
as furniture, curtains, sofas considerably
increase stove distance.
The two side walls of the heat stove must be
accessible for maintenance by authorised
technicians.
40 cm
>120 cm
2