17
To extinguish the heat stove, do not
unplug it but let the automatic extinction
cycle end: prolonged flue gas exhaust
fan operation is normal and may indicate that the
stove is still hot.
In case of low temperatures, moreover, flue gas
exhaust fan and circulating pump may still start
up for a few minutes with stove off, in order to
prevent possible formation of ice in the system's
pipes. In the event of a power outage, when the
Heat stove Cycle On/Off
power supply is restored the heating controller
will expel the residual flue gas, increasing the
extractor's speed and displaying the words “Cool
FIRE”. Upon completing the cooling cycle, the
stove will restart automatically and go back to the
operating mode prior to the power outage.
Internal thermostat
Position of the internal room probe
Only upon completing installation it is
recommended to ensure the room probe is
extracted from its housing and away from the
stove's hot structure, to prevent detecting
incorrect temperatures.
The probe is located at the rear of the stove.
When using the internal thermostat, it is
recommended to always set a slightly higher
temperature by a few degrees (e.g. 22°C if you
wish to have 20°C in the room) because the
probe is in any case affected by the stove's hot
structure.
The external thermostat is not included with the
stove and is at the user's expense.
The stove may be temperature controlled even
by an external room thermostat. It is placed in a
middle position with respect to the installation
room and assures better consistency between
the heating temperature required of the stove and
the one it actually delivers.
Installation
Connect the two wires of the cable from the
thermostat installed on the wall to the connector
terminal. Insert the connector in the suitable
socket at the rear of the stove.
The heat stove may work with the “stove in
modulation” mode (standard) or in ECO-STOP
mode.
After connecting the external
thermostat the internal thermostat is
automatically disabled.
The heat stove is standard supplied
with ECO-STOP mode disabled.
External thermostat
Thermostat